General
HousingReal glass, plastic
Display visible diagonal2.3" (59 mm)
Display resolution [pixels]320 × 240
Colours (similar)RAL 9010 (white), RAL 9005 (black)
Degree of protectionIP20
Dimensions (W × H × D) mounting ring (W × H) depth55 mm × 55 mm × 35 mm, 71 mm × 71 mm, 7 mm
Weight total≈ 90 g
Ambient temperature0…+45°C / -5…+45°C / -5…+45°C
Ambient air humidity (rH) (non-condensing)5...95 %
Storage temperature25...+70°C
Over voltage categoryIII
Pollution degree2
Inputs
Number4
Contact voltage3.3 V
Contact current0.33 mA
Temperature sensor T-NTC (No. 30516) measurement range at input40...+80°C
Maximum cable length T-NTC / digital inputs3 m / 10 m
KNX bus
MediumTP1-256
Configuration modeS-Mode
Maximum group addresses2000
Maximum assignments2000
Communication objects471 / 433 / 379
Nominal voltage30V DC SELV
Electricity consumption≤ 18mA
Connection KNX plug-in terminal conductor diameter0.6…0.8 mm s
Connection KNX plug-in terminal stripping length5 mm
Time until data reception after bus voltage recovery≈ 5 s
Sensors
CO2 measurement range400...5000 ppm
Humidity measurement range5...95 %
Temperature measurement range5…+60°C
The Elsner Cala Touch KNX AQS/TH 3.x, type 70822, is a room controller with integrated sensors for CO2, temperature, and relative humidity. The device serves as a KNX control unit and enables decentralized control and display of room climate parameters, as well as operation of various functions such as heating, ventilation, lighting, and shading within a KNX network. It features a colour touch display with a visible diagonal of 2.3 inches (59 mm) and a resolution of 320 × 240 pixels, supporting various display and control pages. The surface consists of real glass and plastic, with the colour variant deep black (RAL 9005) available. The housing is designed for indoor use and complies with protection class IP20. The dimensions of the mounting ring are 55 mm × 55 mm × 35 mm, the mounting depth is 7 mm, and the total weight is approximately 90 g. The device is designed for an ambient temperature of 0 to +45 °C, with storage temperature ranging from 25 to +70 °C. Relative humidity during operation may range from 5 to 95 %, without condensation occurring.

Applications

The room controller is designed for integration into building automation systems, particularly in residential and office buildings, where intelligent control of room climate and lighting functions is required. It serves as a central interface for capturing environmental data such as CO2 concentration, temperature, and humidity, enabling automated control of ventilation and heating systems. The integrated weekly time switch with eight time periods supports time-based control of functions. The device can also be used as a secondary station for operating another controller, allowing flexible adaptation to existing systems.

Functions and Equipment in Detail

The device features a touch display showing various control pages, including a page for displaying current measurement values, a menu page for device settings, and pages for temperature control, lighting control (switching, dimming, RGB, colour temperature, Human Centric Lighting), shading, window functions, scene control, and bus information. The integrated weekly time switch enables time-based control of functions. There are eight AND and eight OR logic gates, each with four inputs, which can be used to link switching and communication objects. The outputs of the logic gates can be configured as either 1 bit or 2 x 8 bits. Additionally, eight multifunction modules are integrated, enabling calculations, condition checks, or data point type conversions. An integrated setpoint comparator can compare received values and output them. The measurement values for CO2, temperature, and humidity can be used to control threshold-dependent switching outputs. The thresholds can be set via parameters or through communication objects.

Technology Explained Simply

The room controller operates within the KNX network via the TP1-256 medium and supports the S-Mode as a configuration mode. The nominal voltage is 30 V DC SELV, and the current consumption is up to 18 mA. The maximum number of group addresses and assignments is 2000 each. Communication objects are available in three variants: 471, 433, or 379, depending on configuration. The KNX plug terminal supports wire diameters from 0.6 to 0.8 mm and requires a stripping length of 5 mm. After bus voltage is restored, it takes approximately 5 seconds before data can be received. The integrated sensors measure CO2 in the range of 400 to 5000 ppm, relative humidity from 5 to 95 %, and temperature from 5 to +60 °C. An external temperature sensor T-NTC (item 30516) can be connected to one of the four inputs, with a measurement range of 40 to +80 °C for this sensor. The maximum cable length for the T-NTC sensor is 3 m, and for digital inputs, it is 10 m. The contact voltage of the inputs is 3.3 V, and the contact current is 0.33 mA. The sensors enable the calculation of mixed values, with the proportion of internal and external measurement values being adjustable in percentage. Additionally, the bus message checks whether the values for temperature and humidity lie within the comfort zone (DIN 1946), and the dew point is calculated.

Compatibility and Accessories

The device is designed for use in a KNX network and can communicate with other KNX components. It supports integration of external sensors, particularly the temperature sensor T-NTC (item 30516), which can be connected to one of the four inputs. Control of ventilation, heating, and cooling is performed via integrated PI controllers operating based on temperature, humidity, or CO2 concentration. Ventilation control can be single- or two-stage, as can heating and cooling control. Fan-coil control for fan convectors is also supported. Device functions can be linked via communication objects and logic gates, enabling complex control logics.

Mounting and Installation

Mounting is done in a standard installation mounting ring with dimensions 71 mm × 71 mm. The device is installed into the wall plate, with a mounting depth of 7 mm. Installation requires connection to the KNX bus via the integrated plug terminal. The connection cables must be prepared according to the specified stripping length of 5 mm. Device configuration is performed via the S-Mode, with settings made through the touch display. Device settings include configuration of display and control pages, logic gates, multifunction modules, and thresholds for sensor data.

Advantages in Operation

The room controller offers comprehensive control capabilities for room climate and lighting functions within a KNX network. The integrated sensors enable precise capture of environmental conditions, allowing efficient and comfortable control of ventilation, heating, and lighting. The weekly time switch and logic gates enable flexible and automated control. The touch interface is intuitive to use and provides a clear display of current values and functions. Integration into existing KNX systems is simple and does not require additional components. Settings can be made directly on the device via the display, enabling quick adaptation to changing requirements. The device functions are designed for indoor use and meet safety and reliability requirements in building automation.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/701111
qrcode für Elsner 70822 KNX sensor CO2 temp humidity black