Dold 0070011, EAN: 4030641700119

Dold 0070011 RN5897.12/010/61 AC/DC24-60V insulation monitor 1k-250k

Dold 0070011 RN5897.12/010/61 AC/DC24-60V insulation monitor 1k-250k

Lieske Part No. 1001690
Mfg Part No 0070011
EAN-Code 4030641700119
Manufacturer Dold
Here only 632,67 EUR
752,88 EUR incl. VAT

Further information for Dold 0070011 RN5897.12/010/61 AC/DC24-60V insulation monitor 1k-250k

Technical data
ApprovalsDNV, UL
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 1000 (Coupling device) V, DC 0 - 230 V, DC 0 - 1500 (Coupling device) V
Response value1 - 250 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/010
Earth fault indicatorYes
Variant
Alarm value1 - 250 kOhm
Auxiliary voltageAC/DC 24 - 60 V
Contact equipping2 x 1 changeover contact
Prewarning value20 kOhm - 2 MOhm
Approvals and MarkingsUL-listed C/US, CCC, DNV
The insulation monitor RN5897.12/010/61 AC/DC24-60V from Dold is a device for monitoring insulation in IT systems, particularly in ungrounded AC, DC, and mixed AC/DC networks. It belongs to the VARIMETER IMD family and is designed for continuous monitoring of insulation resistance between the network conductors L(+) and L(-) as well as the protective earth conductor PE1/PE2. The device is suitable for use in industrial installations, UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. Monitoring is carried out in accordance with the standard IEC/EN 61557-8, ensuring standardized and reliable operation.

Applications

The insulation monitor is universally applicable in systems with rated voltages up to AC 230 V or DC 230 V. When used with an external pre-stage device (e.g. RL 5898, RP 5898 or RR 5898), higher voltages can be monitored, up to AC 1000 V and DC 1500 V. The maximum network capacitance is 1000 μF, and the device offers optimized response time at high capacitances. Monitoring also occurs when the network is de-energized, ensuring continuous safety functionality.

Functions and Equipment in Detail

The device features two independently adjustable threshold settings: a pre-alarm level (Pre-Alarm) ranging from 20 kΩ to 2 MΩ and an alarm level from 1 kΩ to 250 kΩ. Adjustment is performed via two rotary switches on the front of the device, enabling user-friendly parameterization. Measured values, device parameters, and operating status are displayed on a multi-colored illuminated display. The display allows for quick fault localization through selective earth fault detection for L+ and L-. A trigger output is provided for connection to an insulation fault detection system.

Technology Explained Simply

The insulation monitor measures the insulation resistance between the network conductors and the protective earth conductor PE. When the set threshold values are exceeded, an alarm is triggered. Measurement is performed via a measuring circuit connected to the network under surveillance through terminals L(+) and L(-). The auxiliary voltage is supplied via terminals A1(+) and A2 and is rated at AC/DC 24 to 60 V. The response time is optimized based on the setting of the maximum network capacitance. An automatic and manual self-test ensures device functionality verification. Alarm memory is selectable, and wire break monitoring of the measuring circuit can be disabled, while monitoring of the protective earth connection PE1/PE2 cannot be disabled.

Compatibility and Accessories

The device can be operated both without a pre-stage device and with external pre-stage devices RL 5898, RP 5898 or RR 5898. The pre-stage devices extend the voltage range and enable monitoring of higher rated voltages. Combining with a pre-stage device requires observing the maximum network voltages and connection examples. The auxiliary voltage is available in three wide voltage ranges, with the specified variant using AC/DC 24 to 60 V.

Mounting and Installation

The insulation monitor is designed as an installation distributor with a width of 52.5 mm. Mounting is performed in standard distributor enclosures. The connection terminals are clearly labeled, with auxiliary voltage supplied via A1(+) and A2. Connections L(+) and L(-) are directly connected to the network under surveillance. The PE1/PE2 terminals are used for connection to the protective earth conductor. A tamper-proof transparent cover protects the device against unauthorized manipulation.

Advantages in Operation

Selective earth fault detection for L+ and L- enables quick fault localization. The two independent threshold settings allow for differentiated alarm signaling, e.g. for pre-alarm and alarm. Display of the current insulation resistance and device status on the display supports maintenance and diagnostics. Monitoring even when the network is de-energized ensures continuous safety functionality. Simple adjustment via rotary switches and the option for external control via a test/reset input enhance the device’s usability and flexibility. Certifications UL-listed C/US, CCC and DNV confirm suitability for use in various markets and application areas.