Dold 0069324, EAN: 4030641693244

Dold 0069324 UG9431.12PM DC voltage relay DC24V

Dold 0069324 UG9431.12PM DC voltage relay DC24V

Lieske Part No. 1000854
Mfg Part No 0069324
EAN-Code 4030641693244
Manufacturer Dold
Here only 33,35 EUR
39,69 EUR incl. VAT

Further information for Dold 0069324 UG9431.12PM DC voltage relay DC24V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Nominal voltage max.DC 1000 V
Output contacts2 C/O contacts
Width22,5 mm
TypeUG 9431
Operate delayYes
Variant
Auxiliary voltageDC 24 V
Contact equipping2 changeover contacts
Nominal voltageDC 1000 V
The Dold voltage relay UG9431.12PM is a multifunctional measuring relay of the VARIMETER series, specifically designed for monitoring DC power networks in the range of DC 20 to 1000 V. It is used for detecting overvoltages, undervoltages, and voltage range exceedances, and enables configurable, precise monitoring via a galvanically isolated Modbus RTU interface. The device is designed for use in enclosures and offers a width of 22.5 mm, making it space-saving and suitable for integration into existing installations. The auxiliary voltage is DC 24 V, and the output contacts consist of two changeover contacts, which can be used to control alarms or switching operations.

Applications
This relay is suitable for industrial applications requiring continuous monitoring of DC power supplies, for example in systems with battery storage, photovoltaic systems, or industrial control systems. The ability to set minimum, maximum, or window monitoring allows for flexible adaptation to different operating conditions. Early detection of voltage deviations supports preventive maintenance and increases the operational safety of the entire installation.

Functions and Equipment in Detail
The device features a configurable relay function, where the output state (operating or resting position) can be set according to requirements. The pickup delay, drop-out delay, and start-up bypass time can be individually configured to avoid false alarms and optimize the response to actual disturbances. The hysteresis is adjustable in the range of 0.2 to 50 % of the pickup value, ensuring precise threshold control. A fault memory documents occurring faults, simplifying the diagnosis of malfunctions.

Technology Explained Simply
Monitoring is performed via a voltage measurement input (e+, f), which receives the DC voltage to be monitored. The auxiliary voltage (A1, A2) supplies the device with DC 24 V. The Modbus RTU interface enables communication with higher-level control systems, allowing status information, configuration, and diagnostics to be queried via a serial interface. LED indicators signal the operating status: green LED for operational readiness, red LED for faults, and yellow LEDs for Modbus communication and status indication of the two relay outputs.

Compatibility and Accessories
The relay is designed for use in enclosures and complies with the standard IEC/EN 60255-1. The Modbus RTU interface enables integration into existing automation systems. Assigning monitoring functions to the two relay outputs allows for differentiated alarm signaling, for example, pre-alarm via relay 1 and alarm via relay 2. The rated impulse withstand voltage is 6 kV/2, indicating high insulation strength.

Mounting and Installation
The device is mounted in an enclosure and connected via the designated terminals (A1/A2 for auxiliary voltage, e+/f for voltage measurement input, 11/12/14 and 21/22/24 for relay outputs). The Modbus interface is connected via terminals A and B. The start-up bypass time ensures that no reaction occurs to voltage fluctuations immediately after power-up, preventing false alarms.

Advantages in Operation
Thanks to simple configuration, reduced wiring, and the possibility of remote monitoring via Modbus RTU, maintenance effort is reduced. Differentiated fault messages and the fault memory support rapid fault localization. The combination of compact design, wide measurement range, and high functionality makes the relay a cost-efficient solution for voltage monitoring in industrial installations. Operational safety is increased by early detection of voltage deviations, which improves the availability of the installation.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1000854
qrcode für Dold 0069324 UG9431.12PM DC voltage relay DC24V