Dold 0067526, EAN: 4030641675264

Dold 0067526 UG5124.82PS trip circuit monitor DC40-265V

Dold 0067526 UG5124.82PS trip circuit monitor DC40-265V

Lieske Part No. 1000801
Mfg Part No 0067526
EAN-Code 4030641675264
Manufacturer Dold
Here only 330,88 EUR
393,75 EUR incl. VAT

Further information for Dold 0067526 UG5124.82PS trip circuit monitor DC40-265V

Technical data
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width22,5 mm
TypeUG 5124
Variant
Auxiliary voltageDC 20 - 265 V
Contact equipping2 changeover contacts
Measuring current1,5 mA
Measuring voltageDC 40 - 265 V
The UG 5124 trip circuit monitor from Dold is an electronic monitoring device for control and trip circuits in electrical installations, particularly in power circuit breakers, disconnectors and signal circuits. It is designed for continuous monitoring of the integrity of the trip circuit and detects faults such as interruption of the trip coil, broken wires, increased transition resistances, welded control contacts, as well as missing control or auxiliary voltage. The device operates on the principle of rest current and is designed for use in enclosures, with a width of 22.5 mm.

Applications

The UG 5124 is specifically designed for monitoring trip circuits in power circuit breakers. It is used in industrial and power engineering installations where the reliability of switching operations is critical. Continuous monitoring ensures that immediate action can be taken in the event of a fault, for example by triggering an alarm or deactivating a switch. The galvanic isolation between the measuring circuit and the evaluation unit allows the use of different voltage sources, increasing flexibility in application.

Functions and Equipment in Detail

The device features two changeover contacts as output contacts, used for signaling states. Monitoring is performed via a constant current source that injects a measuring current of 1.5 mA into the circuit to be monitored. This current flows between the poles of the control voltage of the switch being monitored. If the current cannot flow due to a fault, the relay activates. The repeat accuracy is ±2 % of the set value.

Technology Explained Simply

The technology is based on a rest current principle, where a constant measuring current (1.5 mA) flows through the circuit to be monitored. The galvanic isolation of the measuring circuit from the evaluation unit is achieved via an optical isolator, ensuring safe separation between the measuring voltage and the internal electronics. The measuring voltage range is DC 40–265 V, while the auxiliary voltage for the device itself is DC 20–265 V. The constant current source limits power dissipation in the measuring circuit, as the current is largely independent of voltage. This prevents unwanted heating in the monitored circuit.

Compatibility and Accessories

The trip circuit monitor is compliant with IEC/EN 60255-1 and designed for use in industrial installations. The connection terminals are coded plug-in terminals, enabling quick device replacement. Terminal designations are A1+/A2 for auxiliary voltage, M1+/M2 for the measuring circuit, and contacts 15–18 and 25–28 for the two changeover contacts. Switching capacities are defined according to AC 15 (make: 3 A / AC 230 V, break: 1 A / AC 230 V) and DC 13 (1 A / DC 24 V). The electrical service life is 150,000 switching operations at 1 A and AC 230 V.

Mounting and Installation

The device is mounted in enclosures and is designed for installation on a 35 mm DIN rail. The connection terminals are designed for easy and secure connection. Time delay settings are adjusted directly on the front panel via rotary switches, enabling user-friendly commissioning. The connection blocks are plug-in, allowing device replacement without soldering.

Advantages in Operation

The UG 5124 offers a wide auxiliary voltage range of DC 20–265 V, simplifying adaptation to various installation conditions. Galvanic isolation and the constant current source ensure high reliability and minimize load on the monitored circuit. Separate settings for pickup and drop-out time delay allow precise adaptation to the specific requirements of the installation. Integrated LEDs (green: ON, yellow: OK, red: Error) provide visual status indication, with the yellow LED flashing during drop-out delay and the red LED flashing during pickup delay. The thermal current rating is up to 4 A per contact, with the total current limit curve defining the maximum load.