Dold 0061900, EAN: 4030641619008

Dold 0061900 GB9034 100A AC50/60Hz 230V motor brake relay

Dold 0061900 GB9034 100A AC50/60Hz 230V motor brake relay

Lieske Part No. 1001875
Mfg Part No 0061900
EAN-Code 4030641619008
Manufacturer Dold
Here only 1.553,96 EUR
1.849,21 EUR incl. VAT

Further information for Dold 0061900 GB9034 100A AC50/60Hz 230V motor brake relay

Technical data
Braking current adjustable up to max.600 A
Braking time adjustable up to max.320 s
Width110 mm
TypeGB 9034
Automatic standstill monitoringYes
External brake contactor requiredYes
Signalling outputYes
Temperature monitoringYes
Variant
Auxiliary voltageWithout
Braking current100 A
Nominal voltageAC 230 V
Approvals and MarkingsUKCA
The electronic motor brake device GB 9034 of the MINISTOP series by Dold is designed for wear-free braking of three-phase and alternating current asynchronous motors. It is intended for drives that must be reliably and quickly braked for safety and functional reasons, for example in sawmills, centrifuges, woodworking machines, textile machines or conveyor systems. The device operates on the principle of direct current braking with single-phase rectification and enables precise control of the braking process. The nominal voltage is AC 230 V, and the braking current is rated for 100 A, with the current value adjustable up to 600 A. The braking time can be set up to 320 seconds, allowing flexible adaptation to different drive requirements.

Applications

The motor brake device is designed for industrial applications where fast and reliable braking is required. It is particularly used in machines that must not come to a stop by free run for safety reasons. The integrated automatic standstill monitoring ensures that the braking process ends either after the set braking time has elapsed or upon detection of motor standstill. In standstill-dependent braking, a potential-free alarm contact signals if the motor has not come to a stop within the maximum braking time. This enables safe fault detection and response during operation.

Functions and equipment in detail

The device features integrated temperature monitoring, which detects overheating of the motor or heatsink and responds accordingly. The braking function is activated via an external brake contactor, which is controlled via terminals 1/2. The time coordination between switching off the motor contactor and switching on the brake contactor ensures that short-term induction voltages do not damage the power section. The supply voltage is connected to terminals L1–L2, where the interlock contact for the motor contactor closes. The ready LED indicates that the supply voltage is present and the device is operational.

Technology explained simply

Direct current braking is achieved via single-phase rectification, allowing current to flow through the stator winding of the motor and generating a magnetic braking force. The braking time and braking current are adjustable to adapt the braking force to the specific requirements of the drive. The automatic standstill monitoring monitors the motor status and switches off the braking current as soon as the motor stops. This prevents unnecessary energy losses and reduces thermal stress. The width of the device is 110 mm, enabling compact installation in enclosures. The device complies with the standard IEC/EN 60947-4-2 and carries the UKCA mark, confirming conformity with applicable safety requirements.

Compatibility and accessories

The motor brake device is suitable for all asynchronous motors and can be integrated into existing installations. Terminal designations include, among others, the supply voltage (L1–L2), motor connections (U, V, W), protective earth (PE), as well as contacts for interlocking, braking current, and fault signaling. Optional features such as star-delta starting, thermistor motor protection, or a wide voltage range (200–690 V) can be integrated, but are not part of this variant.

Mounting and installation

Mounting is carried out in an enclosure, taking into account the width of 110 mm. The connection terminals are clearly labeled, with the supply voltage connected to L1–L2, the motor to U–V–W, and the external brake contactor to 1–2. The interlock contacts (8–9) ensure that the motor contactor can only be operated again after the braking current has been switched off. The LED indicators (LED 1, LED 2, LED 3) indicate the operating status, with LED 2 showing the current setpoint and LED 3 lighting up when braking current is active. The functions are configurable via terminals Z1–Z4, Z1–X3, and 33–34 for braking interruption, second braking time, and fault signaling.

Advantages in operation

The device offers higher safety through shorter coast-down times and prevents unwanted movements at standstill. It is wear-free and maintenance-free, reducing operating costs. Simple integration into existing installations and adjustable parameters enable flexible use. The automatic standstill monitoring and alarm output ensure reliable fault detection. Conformity with IEC/EN 60947-4-2 and the UKCA mark guarantee compliance with relevant safety and quality standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001875
qrcode für Dold 0061900 GB9034 100A AC50/60Hz 230V motor brake relay