Further information for Dold 0059903 SL9171.12/001 undervoltage relay 3AC400V
Technical data
1- / 3-phase
1, 3
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
3/N AC 500 / 290 V
Output contacts
2 C/O contacts
Width
35 mm
Type
SL 9171
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
3AC 400 V
Response value
0,55 - 1,05 Un
Time delay
without
Variant
Without N. NC circuit operation. Without time delay. Settable response value
The Dold undervoltage relay SL9171.12/001 is an industrial device for monitoring three-phase power networks for undervoltage. It is used for network monitoring and enables automatic switching to a safety power supply or safety lighting in accordance with DIN VDE 0100-710 and DIN VDE 0108. The device operates on the rest current principle, in which the output relay is not activated in the event of a fault, and is designed for use in enclosures. The width is 35 mm, and the housing design is intended for enclosure mounting.
Applications
This relay is used in industrial and commercial installations where reliable network monitoring is required. It monitors three-phase networks for undervoltage and can also be connected single-phase. Applications include ensuring power supply for critical loads such as safety lighting or emergency power units, as well as preventing damage caused by unexpected voltage dips. The variant without time delay is suitable for installations requiring immediate response to voltage dips.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which activate the relevant load or safety function when undervoltage is detected. The pickup value is adjustable and ranges from 0.55 to 1.05 times nominal voltage (Un). The nominal voltage is 3AC 400 V, although the device is also suitable for other voltages up to 3/N AC 500/290 V. Monitoring is performed without auxiliary voltage, simplifying installation and increasing independence from the network. An LED indicator signals the contact position of the output relay.
Technology Explained Simply
Measurement is carried out via the arithmetic mean of the individual phases against the neutral conductor. For variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). In single-phase operation, terminals L1, L2, and L3 must be connected. The device is independent of phase sequence and detects undervoltage regardless of phase order. Pickup delay is active, but in this variant, no time delay is provided for resetting to the normal state.
Compatibility and Accessories
The device is designed for use in enclosures with mounting plate and cable duct. It is available in S-form, which has a depth of 98 mm and top-mounted terminals. The devices are certified in accordance with IEC/EN 60255-1.
Mounting and Installation
Mounting is carried out in enclosures with a mounting plate. The terminals are located at the top, which facilitates wiring within the enclosure. The width of 35 mm allows standard mounting on DIN rails. The devices are designed for frequencies between 45 and 65 Hz and can be continuously loaded at 1.15 times nominal voltage.
Advantages in Operation
The relay provides reliable network monitoring without auxiliary voltage, simplifying installation and maintenance. The adjustable pickup voltage allows flexible adaptation to different requirements. The LED indicator facilitates diagnosis of the operating status. The rest current principle ensures that the output relay is not activated in the event of a fault, increasing safety. The devices are designed for use in industrial environments and comply with applicable standards.