| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | BG 5924 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | AC/DC 24 V |
| Approvals and Markings | UL-rec. C/US, TÜV, UKCA, CCC |
The Dold BG5924.04/61AC/DC24V is a
not-out module for use in safety-oriented systems. It is designed for the safe release and interruption of safety circuits to protect personnel and machinery from hazards. The device is designed for use in industrial environments where high reliability and safety integrity are required. It features a
width of 22.5 mm and is therefore suitable for installation in standard control panels. The nominal voltage is
AC/DC 24 V, allowing flexible use in various operating voltage environments.
Applications
This module is intended for applications in industrial automation, particularly in areas where safe shutdown is necessary in hazardous situations. It complies with the requirements of standard
EN 50156-1 for heating systems, confirming its suitability for safety-critical systems in heating and energy technology. It is typically used in conjunction with emergency stop switches, safety light curtains, or other safety sensors that use the module to safely interrupt the control of drives, motors, or other machine components.
Functions and Equipment in Detail
The device provides a
contact configuration with 4 NO contacts, which can be used to control multiple loads or safety functions. The outputs are rated for a
thermal current Ith max. of 5 A, covering the load capacity for typical industrial applications. The connection technology uses
removable screw terminals, enabling flexible and secure wiring connections. The terminals are designed for stranded wires with a cross-section up to 2.5 mm², and the use of ferrules and plastic collars according to DIN 46228-1/-2/-3/-4 is also possible. This ensures a robust and reliable connection, even under industrial conditions.
Technology Explained Simply
The module operates on the principle of
safety-oriented circuitry, where functions such as start, operation, and shutdown are secured via redundant channels. It supports both
single-channel and dual-channel wiring, allowing a higher safety level to be achieved depending on requirements. The integrated
LED indicators show the operating status and the status of individual channels, facilitating error diagnosis during operation. A
short-circuit detection between terminal Y1 and ground provides additional safety by detecting potential faults early. Safety integrity is confirmed by certifications
PL e / Cat. 4 according to EN ISO 13849-1 and
SIL 3 according to IEC/EN 62061, highlighting its suitability for high-safety applications.
Compatibility and Accessories
The module is designed for use in systems with
AC/DC 24 V and can be combined with other safety components operating at the same voltage. Certifications
UL-rec. C/US, TÜV, UKCA, CCC confirm compliance with international safety standards, enabling use in various markets. It is part of the
BG 5924 product family, which also includes other variants with different voltages and contact configurations. The use of
removable terminal blocks simplifies installation and maintenance, as the terminals can be removed and replaced as needed.
Mounting and Installation
Mounting is done in standard control panels with a width of 22.5 mm. The terminal blocks are removable, simplifying installation and maintenance. The connection terminals are designed for stranded wires up to 2.5 mm², and the use of ferrules and plastic collars according to DIN 46228-1/-2/-3/-4 is recommended. Correct wiring according to the circuit diagrams in the datasheet is essential for proper function. Installation should be carried out by qualified personnel to ensure safety functions are maintained.
Advantages in Operation
The module offers high safety integrity through certifications PL e / Cat. 4 and SIL 3, making it suitable for critical applications. The integrated LED indicators allow for quick visual inspection of the operating status. Removable terminal blocks simplify maintenance and repair. Support for single- and dual-channel wiring provides flexibility in system design. Compliance with international standards such as EN 50156-1, EN ISO 13849-1, and IEC/EN 62061 ensures reliability and acceptance across various industries.