Dold 0059335, EAN: 4030641593353

Dold 0059335 GF9016 3AC50/60Hz 400V 11kW soft starter

Dold 0059335 GF9016 3AC50/60Hz 400V 11kW soft starter

Lieske Part No. 1002142
Mfg Part No 0059335
EAN-Code 4030641593353
Manufacturer Dold
Here only 528,65 EUR
629,09 EUR incl. VAT

Further information for Dold 0059335 GF9016 3AC50/60Hz 400V 11kW soft starter

Technical data
Extra functionsMains monitoring, Temperature monitoring
For three-phase motors, 400 V up to22 kW
Load voltage up to3AC 400 V
Width45 mm, 52,5 mm
TypeGF 9016
Signalling outputYes
Variant
Auxiliary voltageWithout
Mains / motor voltage3AC 400 V
Nominal motor power11 kW
Approvals and MarkingsUKCA
The soft starter GF 9016 from Dold is an electronic control device for smooth start-up and shut-down of three-phase asynchronous motors. It reduces mechanical stress in the drive system and relieves the supplying network by reducing inrush currents. The device operates with a 2-phase motor control via power semiconductors (thyristors), enabling currents and motor torque to increase gradually. This ensures a jerk-free start-up, increasing the service life of motors and mechanical drive components. After start-up, the power semiconductors are bypassed via internal relay contacts to minimize power losses in the device. The soft shut-down function extends the natural coast-down time to avoid abrupt stopping of the drive.

Applications
This device is suitable for drives with gear, belt, or chain transmission, particularly in systems such as conveyor belts, fans, pumps, compressors, woodworking machines, centrifuges, packaging machines, and door drives. It is designed for 3-phase asynchronous motors operated at a supply voltage of 3AC 400 V. The maximum motor power is up to 22 kW, with the current variant designed for a motor with a rated power of 11 kW.

Functions and Equipment in Detail
The device offers separate adjustment options for start-up and shut-down time, as well as for start-up voltage. Optionally, a kick-start function can be activated, providing a short impulse at the beginning of start-up to ensure the motor starts reliably. Control is performed without auxiliary voltage, simplifying installation. The W3 circuit configuration is possible, enabling flexible connection to existing systems. An alarm output is integrated, which can be used for monitoring the operating status.

Technology Explained Simply
The phase-cut control via thyristors enables controlled voltage regulation on two motor phases. This allows the motor torque to be built up gradually, minimizing mechanical stress. Network monitoring and temperature monitoring ensure safe operation. In case of faults, a yellow LED blinks at a specific frequency indicating the fault code. A green LED indicates the ready-to-operate status. The fault codes include supply voltage faults, overload, electronic faults, ignition faults in phases, and motor phase faults.

Compatibility and Accessories
The device is designed for 3-phase motors up to 22 kW at 400 V. It complies with the standard IEC/EN 60947-4-2. The width is 45 mm for motors up to 15 kW and 52.5 mm for motors up to 22 kW. The terminal designation includes supply voltage, control for bypassing, ignition pulse generator, ramp control, and signal outputs for fault and device bypass. The terminals are clearly labeled to facilitate easy installation.

Mounting and Installation
Mounting is done in an enclosure or distribution. The width of 52.5 mm (for 11 kW) allows for space-saving installation. The terminals are intended for connection to supply and motor voltages, as well as for control inputs and outputs. The terminal designation is detailed in the data sheet. Installation is performed without auxiliary voltage, simplifying wiring.

Operational Advantages
Smooth start-up and shut-down reduce wear on motors and mechanical components. The service life of drive parts is extended. Network relief through reduced inrush currents protects the supply infrastructure. Simple mounting and space-saving installation facilitate integration into existing systems. Integrated network and temperature monitoring, along with fault indication via LED signals, enable quick diagnosis during operation.

Approvals and Markings
The device carries the UKCA marking, confirming compliance with applicable European safety and performance requirements. Compliance with the standard IEC/EN 60947-4-2 ensures reliability and safety in industrial use.

Device Type and Identification
The device type is GF 9016. Identification is done by specifying the supply voltage (3AC 400 V), motor power (11 kW), and frequency (50/60 Hz). The width of 52.5 mm is intended for motors up to 22 kW, which includes the current variant.

Terminals and Signal Outputs
The terminal designation includes supply voltage (L1, L2, L3), motor voltage (T1, T2, T3), start/stop input (X2), kick-start input (X3), 0-V input (X4), and alarm outputs for fault (X5, X6) and device bypass (X7, X8). The signal outputs enable integration into higher-level control systems.

Fault Diagnosis
The yellow LED blinks at a specific frequency indicating one of eight fault codes. These include supply voltage faults, overload, electronic faults, ignition faults in phases, and motor phase faults. The green LED indicates the ready-to-operate status. The fault codes allow for quick identification of faults during operation.

Operational Safety
Integrated network and temperature monitoring ensure safe operation. In case of critical temperatures or voltage failures, the device is switched off to prevent damage. Fault indication via LED signals enables quick response to malfunctions.

Application Areas
The device is suitable for a wide range of industrial drives, particularly in conveyor technology, packaging industry, woodworking, and systems with pumps, fans, and compressors. Reducing inrush currents protects supply networks and extends the service life of drive components.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1002142
qrcode für Dold 0059335 GF9016 3AC50/60Hz 400V 11kW soft starter