Further information for Dold 0058933 load monitor BH9097.38/0013AC400VAC8A
Technical data
1- / 3-phase
1, 3
Enclosure design
Switch cabinet
Measuring range max.
40 A (37 kW)
Output contacts
2 x 1 C/O contacts
Width
45 mm
Type
BH 9097
Operate delay
Variant
Auxiliary voltage
Without
Contact equipping
2 x 1 changeover contact
Nominal current max
AC 8 A
Nominal voltage
3AC 400 V
Variant
3-phase without auxiliary supply. Start up delay time 0 - 30 s
The load monitor BH 9097.38/0013AC400VAC8A from Dold is an industrial monitoring device of the VARIMETER series, designed for continuous monitoring of load on electrical drives, particularly motors. The device monitors active power and responds to exceeding or falling below adjustable threshold values by activating the output relays. It is designed for use in enclosures and offers a width of 45 mm, enabling compact installation in standard switchboards.
Applications
The load monitor is suitable for monitoring industrial motors with variable load. It can be used in systems where early detection of load anomalies is important to prevent damage to motors or driven machinery. Applications include single-phase and three-phase systems, with the three-phase version requiring symmetrical loading of all phases, as is typical for motor loads. The maximum measurable current is 40 A, corresponding to a power of 37 kW at 690 V or 22 kW at 400 V.
Functions and Equipment in Detail
The device features two independent output relays, each with a single changeover contact, designated for underload (P1) and overload (P2) signaling. The threshold values for P1 and P2 can be set via rotary switches as absolute values in watts. Configuration is performed using DIP switches, allowing the device to operate either as an under- and overload monitor (P1min/P2max) or as an overload monitor with a warning stage (P1max/P2max). The relays can be switched between operating current principle (activated in fault condition) and resting current principle (not activated in fault condition).
Technology Explained Simply
Measurement is performed based on the principle of active power measurement. The device detects the load based on electrical power and compares it with the set threshold values. To suppress short-term load fluctuations, an adjustable response delay tv is provided for each relay. A common adjustable start-up bypass time ta (0–30 seconds) prevents false alarms during motor start-up. Status indication is provided via LEDs: a green LED indicates mains voltage, while two yellow LEDs indicate the status of relays P1 and P2. Blinking LEDs indicate time intervals (e.g., start-up bypass time or response delay), while continuous illumination indicates that the respective relay is active.
Compatibility and Accessories
The device is designed for three-phase systems with nominal voltage 3AC 400 V and can also be used in single-phase installations. It is operational without auxiliary voltage and does not require external power supply. The maximum rated current is AC 8 A. Measurement is possible up to 40 A without external current transformer. Configuration is performed via DIP switches, allowing switching between functions for memory behavior (S1/S2 ON = manual reset, OFF = automatic reset) and operating mode (operating or resting current principle).
Mounting and Installation
The load monitor is intended for mounting in enclosures and is installed in standard switchboards with a width of 45 mm. The connection terminals are designed for connection to load conductors. Commissioning is facilitated by a test/reset button, which also serves as an adjustment aid. The terminal assignment is detailed in the datasheet, with contacts 11–14 and 21–24 designated for relay outputs.
Advantages in Operation
Early detection of load anomalies enables preventive maintenance and reduces the risk of machine failures. Automatic range switching ensures a wide measurement range without additional components. The clear LED indication and simple configuration via DIP switches and rotary switches reduce wiring effort and simplify commissioning. Compliance with standard IEC/EN 60255-1 ensures reliability and safety in industrial applications.
Fault Detection
The device signals two fault conditions via LEDs: if measurement voltage is missing, all three LEDs blink sequentially, indicating a measurement error. In case of reverse power (negative load), all LEDs blink simultaneously, indicating incorrect current connection or reverse power. The output relays signal these fault conditions.