Dold 0056951, EAN: 4030641569518

Dold 0056951 current relay BA9053/010 AC1,5-15A AC230V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0056951 current relay BA9053/010 AC1,5-15A AC230V

Lieske Part No. 1312717
Mfg Part No 0056951
EAN-Code 4030641569518
Manufacturer Dold
Here only 263,30 EUR
313,33 EUR incl. VAT

Further information for Dold 0056951 current relay BA9053/010 AC1,5-15A AC230V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width45 mm
TypeBA 9053
Operate delayYes
Variant
Auxiliary voltageAC 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 1,5 - 15 A
Start up delayWithout
Switching delay0 - 100 s
Approvals and MarkingsUKCA, CCC
VariantOvercurrent relay. Energized on trip. Time delay at response value
The Dold current relay BA9053/010 is an overcurrent relay of the VARIMETER series, designed for monitoring single-phase DC and AC power networks. It is used for continuous measurement and monitoring of the current consumption of electrical loads to detect deviations from the setpoint at an early stage. Device settings are adjusted via rotary switches on the front panel, ensuring simple and user-friendly configuration. Applications include industrial and railway systems, where high operational reliability and preventive maintenance are essential.

Applications
This relay is intended for use in industrial plants and rail transport, where it monitors the current consumption of motors, transformers, or other loads. It enables early detection of overloads or undercurrent conditions to prevent failures. The function as an overcurrent relay is standard, but it can also be used as an undercurrent relay, with hysteresis dependent on the setpoint. The device is installed in enclosures, with a width of 45 mm allowing compact mounting in standard control panels.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, galvanically isolated from the measuring circuit. The auxiliary voltage is AC 230 V, supplied via the network. The measuring ranges cover AC 1.5 to 15 A, with the measured value determined as the arithmetic mean of the rectified current. The devices are calibrated for sinusoidal AC currents in RMS value. Settings are adjusted via rotary switches, allowing both the pickup value and the drop-out value (hysteresis) to be configured.

Technology Explained Simply
The switching delay is 0 to 100 seconds and is activated once the set threshold is exceeded. This delay prevents false alarms caused by short-term current peaks, such as those occurring during motor start-up. The pickup delay is also integrated, so the relay does not react immediately but includes a short delay to filter disturbances. LED indicators signal the operating status: a green LED lights up when auxiliary voltage is applied, and a yellow LED indicates the activated output relay. Galvanic isolation between the auxiliary circuit and measuring circuit ensures safe and interference-free signal transmission.

Compatibility and Accessories
The relay complies with IEC/EN 60255-1 and IEC/EN 60947-1 standards. Certifications UKCA and CCC are available, enabling use in respective markets. It is designed for mounting in enclosures and can be ordered in various versions with different measuring ranges and functions (e.g., with start-up bypass or memory behavior). The variant described here does not include a start-up bypass.

Mounting and Installation
Mounting is performed in standard enclosures with a width of 45 mm. The terminal connections are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Installation requires no special tools; settings are adjusted directly on the front of the device. The terminals are designed for connection with wires, with maximum permissible currents and voltages conforming to technical specifications.

Operational Advantages
Continuous monitoring and the possibility of preventive maintenance increase operational reliability. Rapid fault localization enables efficient maintenance. High overload capacity and a measuring frequency up to 5 kHz ensure reliable operation even under demanding conditions. LED indicators provide a quick visual overview of the operating status, simplifying maintenance. Galvanic isolation between measuring and auxiliary circuits enhances safety and prevents interference in the control circuit.