Dold 0056235, EAN: 4030641562359

Dold 0056235 IL5880.12 DC24V insulation monitor 5–100 kΩ

Dold 0056235 IL5880.12 DC24V insulation monitor 5–100 kΩ

Lieske Part No. 1001719
Mfg Part No 0056235
EAN-Code 4030641562359
Manufacturer Dold
Here only 240,36 EUR
286,03 EUR incl. VAT

Further information for Dold 0056235 IL5880.12 DC24V insulation monitor 5–100 kΩ

Technical data
Enclosure designDistribution board
IMD typeAC
Nominal voltage IT systemAC 0 - 500 V
Response value5 - 500 kΩ
Response value typeAdjustable
Width35 mm
TypeIL 5880
Earth fault indicatorYes
Variant
Alarm value5 - 100 kOhm
Auxiliary voltageDC 24 V
Contact equipping2 changeover contacts
Prewarning valueWithout
Approvals and MarkingsUKCA, CCC
VariantAdjustable alarm value. De-energized on trip
The insulation monitor IL5880.12 DC24V from Dold is a device for monitoring the insulation resistance in ungrounded AC and DC networks (IT systems) with a nominal voltage of AC 0 to 500 V. The device operates on the principle of residual current, whereby the output relay is not activated in the event of a fault, ensuring a safe and reliable fault indication. The auxiliary voltage is DC 24 V, enabling monitoring of de-energized systems as well. The trigger values are adjustable via a potentiometer on the front of the device, with the alarm threshold adjustable between 5 and 100 kΩ. The operating status is indicated by LEDs, with a red LED illuminating in the event of a ground fault. The width is 35 mm, and the device is designed for mounting in installation distributors according to DIN 43880. The housing design is configured as an installation distributor, with connection terminals located at the bottom. The devices comply with the standard IEC/EN 61557-8 and are certified with UKCA and CCC approvals.

Applications

The insulation monitor is suitable for pure AC and DC networks in the frequency range of 10 to 10000 Hz. It is particularly used in industrial plants, railway applications, and systems with mobile power generators, where high safety and reliability of electrical installations are required. The ability to monitor even de-energized networks allows testing of consumers that must be switched on in emergencies, such as motor windings.

Functions and Features in Detail

The device features two changeover contacts as contact configuration, which can be used to trigger alarm signals or switching operations. The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. Programming is performed via connections LT1 and LT2, where bridging these connections activates the hysteresis behavior. Additionally, external reset and test buttons can be connected, facilitating integration into existing monitoring systems. The LED indicators signal operational readiness (green LED), insulation fault (red LED), and for variants with a pre-alarm threshold, also the pre-alarm state (yellow LED). In this variant, no pre-alarm threshold is included.

Technology Explained Simply

The insulation monitor measures the resistance between the electrical network and ground. If this resistance falls below the set alarm threshold, a fault is detected and signaled via the LEDs and relay contacts. The galvanic isolation between the measuring circuit, auxiliary voltage, and output contacts ensures high safety and prevents interference in the monitored system. The trigger value is adjusted via a potentiometer located directly on the front of the device, enabling user-friendly adaptation to specific requirements.

Compatibility and Accessories

The device is designed for IT systems with a nominal voltage of AC 0 to 500 V and can be used in various application areas, including industrial and railway applications. It is available in various housing designs, with the IL5880.12 DC24V variant designed for installation distributors. Mounting is possible either on DIN rails or by screws. The width of 35 mm allows flexible placement in standard distributor enclosures. The devices are certified with UKCA and CCC approvals, enabling use in corresponding markets.

Mounting and Installation

Mounting is performed in installation distributors according to DIN 43880. The connection terminals are located at the bottom of the device, enabling easy wiring. The auxiliary voltage is supplied via connections A1 and A2, while the lines to be monitored are connected to L and N. The protective earth conductor is connected to PE. Relay function programming is performed via connections LT1 and LT2. The LED indicators allow visual inspection of the operating status.

Advantages in Operation

The insulation monitor provides preventive fire and system protection through early detection of insulation faults. The simple adjustment of trigger values and clear LED indication simplify maintenance and monitoring. Galvanic isolation and the residual current principle enhance the safety and reliability of the device. The ability to connect external buttons enables flexible integration into existing systems. Monitoring even when the network is de-energized extends the application range to applications where electrical power is temporarily switched off.