| Technical data |
| 1- / 3-phase | 1, 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Measuring range max. | 8 A |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 9065 |
| Variant |
| Contact equipping | 1 changeover contact |
| Current range | 0,4 - 8 A |
| Nominal voltage | 3AC 400 V |
| Operate delay | 1 - 100 s |
| Variant | Without auxiliary supply. Manual reset programmable. Selection de-energized or energized on trip |
The underload monitor
IK9065.11/100 3AC400V 0,4-8A from Dold is an industrial monitoring switch for detecting underload and no-load conditions in asynchronous motors. The device monitors the phase shift between current and voltage (cos ϕ), which changes with the motor load. This measurement method enables reliable monitoring independent of motor size and is particularly suitable for applications such as fan monitoring (e.g. in case of belt breakage), filter monitoring (in case of blockage) or centrifugal pump monitoring (in case of valve closure or dry running). The device is designed for use in industrial and railway applications and complies with the standard
EN 60255-1.
Applications
The underload monitor is intended for monitoring single- and three-phase alternating and rotating current loads, particularly asynchronous motors. It is direction-independent and can also be used for general cos ϕ monitoring. The direct connection capability for motors with a rated current of up to approximately 5 A (at 3AC 400 V, corresponding to a motor power of 1.5 to 2.2 kW) makes it especially suitable for smaller drives. For higher currents, an external current transformer can be connected.
Functions and equipment in detail
The device features
1 changeover contact as output contact and operates without auxiliary voltage. The response delay is adjustable in the range of
1 to 100 seconds, allowing adaptation to different system conditions. The response value for cos ϕ is also adjustable. If the set cos ϕ value is undershot for the duration of the set delay time, the output relay is switched to alarm position and the red ALARM LED lights up. The operating mode is programmable: it can be set to automatic reset (Alarm Auto Reset) or latched alarm (Latched Alarm). Additionally, the idle / active current principle is switchable, with the device operating standardly in idle current mode (output relay not activated in fault condition). An integrated RESET button and the possibility of remote RESET are included.
Technology explained simply
The operation is based on measuring the phase shift between voltage and current. At low load (underload or no-load), the cos ϕ value changes, which is detected by the device. The measurement is performed via the current path L1-L1', which directly evaluates currents up to 8 A. The connection terminals are located at the bottom, enabling installation in installation and industrial distributors according to DIN 43880. The width is
17.5 mm, the depth 58 mm. The housing design is intended for installation distributors. The LED indicators for power supply and alarm allow quick visual status monitoring.
Compatibility and accessories
The device is designed for direct connection of motors with a rated current of up to approximately 5 A. For higher currents (above 8 A), an external current transformer can be connected. The variant SL 9065CT offers an integrated through-type transformer for currents up to 100 A, however, this is not the IK9065 variant described here. Mounting is done via DIN rail or screw mounting.
Mounting and installation
Mounting is done in installation and industrial distributors according to DIN 43880. The connection terminals are located at the bottom. When used with motors, ensure that the motor is connected to L1' and not to L1 to ensure correct phase shift measurement. For single-phase loads, terminal L3 is not connected.
Advantages in operation
By detecting underload and no-load conditions early, the underload monitor enables preventive maintenance, preventing costly damage. The operational safety and availability of the system are thus increased. The programmable operating mode (automatic reset or latched alarm) and the switchable idle / active current principle expand the range of applications. The integrated RESET function and LED indicators facilitate diagnosis and maintenance during operation.