Dold 0054792, EAN: 4030641547929

Dold 0054792 undercurrent relay AC220-240V 0.1-50A

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0054792 undercurrent relay AC220-240V 0.1-50A

Lieske Part No. 1583545
Mfg Part No 0054792
EAN-Code 4030641547929
Manufacturer Dold
Here only 257,07 EUR
305,91 EUR incl. VAT

Further information for Dold 0054792 undercurrent relay AC220-240V 0.1-50A

Technical data
1- / 3-phase1
Enclosure designDistribution board
Output contacts1 C/O contact, 2 C/O contacts
Width35 mm
TypeIL 9271
Operate delayYes
Variant
Auxiliary voltageAC 220 - 240 V
Contact equipping1 changeover contact
Measuring range0,1 - 50 A
Switching delay0,1 - 20 s
Approvals and MarkingsUKCA, CCC
VariantSingle phase current relay. De-energized on trip. With 5 measuring ranges settable with switch
The Dold undercurrent relay IL9271.11/500 is a single-phase current monitoring device for alternating and rotating current networks, designed for use in installation and industrial distribution systems. It monitors current flow and de-energizes the output contact when the set pickup value is undershot, applying the rest current principle – meaning the output relay is not activated in the event of a fault. The auxiliary voltage is AC 220–240 V, and the device features an adjustable measuring range from 0.1 to 50 A, which can be set in five steps via a rotary switch. The switching delay is also adjustable and ranges from 0.1 to 20 seconds. The width is 35 mm, and the device is designed for mounting in installation distributors according to DIN 43880.

Applications
IL9271.11/500 is suitable for monitoring electrical systems where continuous current flow is required, for example in pump control systems, fan installations, or for monitoring motors and transformer systems. It is used to trigger a reaction in case of undercurrent situations, which may indicate malfunction, short circuit, or interruption in the circuit, such as switching off a motor or triggering an alarm. The galvanic isolation between the auxiliary circuit and the measuring circuit ensures safe and interference-free measurement.

Functions and Equipment in Detail
The device features a changeover contact as output contact, which is de-energized under undercurrent conditions. The pickup values are adjustable via a rotary switch, with hysteresis fixed at approximately 4%. LED indicators signal the operating status: a green LED lights up when current is within the specified limits (normal condition), and a red LED lights up in case of undercurrent. The switching delay allows for time-delayed response, filtering out short-term current fluctuations and avoiding false tripping.

Technology Explained Simply
IL9271.11/500 operates on the rest current principle, where the output contact is active during normal operation and de-energized under undercurrent conditions. This is particularly useful in systems where power failure requires immediate reaction. Measurement is performed via a current measuring circuit, galvanically separated from the auxiliary circuit, to avoid interference and voltage influences. The auxiliary voltage is supplied via terminals A1 and A2, while the current measuring circuit is connected via terminals i and k. The measuring ranges are set via a rotary switch, which allows five different settings.

Compatibility and Accessories
The device is designed for use in single-phase networks and can be mounted in installation distributors according to DIN 43880. It is compatible with other devices from the IL and SL series, which also offer single-phase monitoring functions. The width of 35 mm allows mounting in standard distribution boxes. The connection terminals are arranged at the bottom, typical for the I form factor. IL series devices are available in various variants, with IL9271.11/500 being the variant with 5 adjustable measuring ranges and 1 changeover contact.

Mounting and Installation
Mounting is done in an installation distributor with a width of 35 mm. The connection terminals are located at the bottom, facilitating integration into existing control systems. The auxiliary voltage is connected via terminals A1 and A2, and the current measuring circuit via i and k. The measuring range settings are adjusted via a rotary switch located on the front of the device. The LED indicators serve for visual monitoring of the operating status.

Advantages in Operation
IL9271.11/500 offers precise and reliable current monitoring with adjustable parameters that can be adapted to the specific requirements of the system. The galvanic isolation between measuring and auxiliary circuits ensures high safety. The LED indicators allow for quick visual control of the operating status. The adjustable switching delay reduces the likelihood of false tripping due to short-term current fluctuations. The device complies with standards IEC/EN 60255-1 and is certified with UKCA and CCC, confirming compliance with European and Chinese safety standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1583545
qrcode für Dold 0054792 undercurrent relay AC220-240V 0.1-50A