Further information for Dold 0053943 BH9097.38AC230VAC24A load monitor
Technical data
1- / 3-phase
1, 3
Enclosure design
Switch cabinet
Measuring range max.
40 A (37 kW)
Output contacts
2 x 1 C/O contacts
Width
45 mm
Type
BH 9097
Operate delay
Variant
Auxiliary voltage
Without
Contact equipping
2 x 1 changeover contact
Nominal current max
AC 24 A
Nominal voltage
AC 230 V
Approvals and Markings
CCC
Variant
1-phase without auxiliary supply. Start up delay time 0 - 30 s
The load monitor BH9097.38AC230VAC24A from Dold is an industrial monitoring switch of the VARIMETER series, designed for continuous monitoring of the electrical load of motors and other electrical consumers in industrial applications. The device detects overload and underload conditions by measuring active power, and responds to exceeding or falling below adjustable threshold values by activating the output relays. The functionality is designed for applications in enclosures, with a width of 45 mm enabling compact mounting in standard control panels.
Applications
The load monitor is suitable for monitoring electrical industrial drives with variable load, particularly motors with a power up to 22 kW at 400 V or up to 37 kW at 690 V. It can be used in both single-phase and three-phase systems, with the measurement principle based on single-phase measurement and assuming symmetrical loading of all phases, as is typical for motor loads. The application is in industrial environments, where early detection of load anomalies contributes to avoiding machine failures and enabling planned maintenance.
Functions and Equipment in Detail
The device features two independent output relays, each with a single-pole changeover contact, intended for signaling two different load conditions (P1 and P2). The threshold values for P1 and P2 can be set via rotary switches as absolute values in watts. The setting is done via an absolute scale, ensuring precise and reproducible configuration. The relays can be switched via DIP switches to either operating current principle (relay activated in fault condition) or resting current principle (relay deactivated in fault condition). Additionally, a memory behavior can be set, with options S1/S2 ON (manual reset) and S1/S2 OFF (automatic reset) available.
Technology Explained Simply
Measurement is performed via active power measurement, with the device capable of measuring up to 40 A without an external current transformer. Automatic range switching enables a wide measurement range. A common start-up bypass time ta (0 to 30 seconds) prevents false alarms during motor start-up. Indication is provided via two yellow LEDs (for P1 and P2) and one green LED (for mains voltage). The LEDs indicate the operating status: flashing shows the time delay progression, steady light indicates relay activation. In case of faults, such as missing measurement voltage or reverse power, all LEDs flash in specific patterns.
Compatibility and Accessories
The device is configurable for single-phase and three-phase systems and requires no auxiliary voltage. It is compliant with IEC/EN 60255-1. Wiring is done via terminals A1/A2, U, T/k, L/i, with contacts 11-14 and 21-24 representing the output relays. Configuration is done via DIP switches and rotary switches, with a test/reset button aiding commissioning and adjustment. The CCC certification is specified.
Mounting and Installation
Mounting is done in enclosures, with the width of 45 mm enabling installation in standard control panels. The terminals are clearly labeled, and settings are adjusted via mechanical switches. Installation requires no additional auxiliary voltages, as the device operates without auxiliary voltage. Wiring is simplified, as the relays directly indicate load conditions.
Advantages in Operation
Early detection of load anomalies enables preventive maintenance and prevents costly damage. The clear LED indication and adjustable time delays reduce false alarms. Configurability for operating or resting current principle, as well as the choice between underload and overload monitoring or overload monitoring with a warning stage, expands application possibilities. Automatic range switching and measurement up to 40 A without an external current transformer reduce installation effort. Compliance with the standard IEC/EN 60255-1 ensures reliability and safety in industrial operation.