Further information for Dold 0053870 BD5935.48/824 DC24V emergency stop module
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
1 NC contact, 3 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
45 mm
Type
BD 5935
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 1 NC contact
Nominal voltage
DC 24 V
Approvals and Markings
TÜV, UKCA, CCC
Variant
With fast auto start: typ. 110 ms, without line fault detection on ON-button
The Dold safety relay BD5935.48/824 DC24V is an emergency stop module for use in safety-oriented systems. It is designed for the safe interruption of circuits, particularly in conjunction with emergency stop buttons and safety doors, to protect personnel and machinery. The device is designed for operating voltages of DC 24 V and features a contact configuration with 3 NO contacts and 1 NC contact. It is available as a 1- or 2-channel variant, allowing flexible integration into different safety architectures.
Applications
The BD5935 is designed for use in industrial systems where a safe response to emergency stop commands or the opening of safety doors is required. It is particularly used in machine building, manufacturing systems, and systems with moving parts where the risk of injury exists. The function as a safety door monitor enables monitoring of access doors, ensuring that machine operation is automatically shut off when a door is opened. The wire break detection on single-button ensures that a defective or interrupted button is detected, increasing the reliability of the safety function.
Functions and equipment in detail
The device features an operating status indicator with LED displays for channel 1 and 2, visually signaling the current state of the relay. The removable screw terminals allow for quick replacement of the device without rewiring, simplifying maintenance and repair. The contacts are gold-plated, making them particularly suitable for switching small loads, such as signals to a PLC. The cross-connection detection in the emergency stop control circuit detects unauthorized connections between channels, ensuring the integrity of the safety system.
Technology explained simply
The safety relay operates according to standards for safety-related control systems. It achieves a Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest requirement for safety functions. Additionally, it meets the requirements for SIL 3 according to IEC/EN 62061 and IEC/EN 61508, ensuring reliability in critical applications. The thermal current Ith max. is 10 A, indicating the maximum load capacity of the contacts. The width of 45 mm allows for compact mounting in standard control panels. The overvoltage and short-circuit protection function protects the device from damage due to electrical disturbances.
Compatibility and accessories
The BD5935 is designed for use with emergency stop buttons and safety door contacts. The connection technology supports wires with cross-sections up to 2 x 2.5 mm² with ferrules according to DIN 46228-1/-2/-3/-4. It is equipped with fast auto-start, typically taking 110 ms, enabling quick operational readiness after power-up. The variant without wire break detection on single-button is specifically intended for applications where this function is not required.
Mounting and installation
Mounting is done in standard control panels with a width of 45 mm. The removable terminals simplify installation and maintenance. The connection terminals are designed for use with wires and ferrules, ensuring a secure and durable connection. Device programming is done via electrical wiring, with functions such as auto-start and cross-connection detection predefined by the variant selected.
Advantages in operation
The combination of high safety requirements, fast start-up, and easy maintenance makes the BD5935 a reliable component in safety-critical systems. The LED indicators allow for quick visual inspection of the operating status. The certifications TÜV, UKCA, CCC, and UL-Recognized confirm compliance with international safety standards. The gold-plated contacts ensure high service life and reliability when switching signals.
Certifications and markings
The device complies with the requirements of standards EN ISO 13849-1, IEC/EN 62061, and IEC/EN 61508. The certifications TÜV, UKCA, CCC, and UL-Recognized confirm compliance with respective safety and quality standards. These certifications are relevant for use in various markets and industries, particularly in industrial and machine building applications.
Use in safety-critical systems
The BD5935 is designed for use in systems requiring high safety integrity. The combination of fast auto-start, cross-connection detection, and wire break detection ensures a reliable response to faults. The certifications and safety standards guarantee that the device can be used in critical applications without compromising safety levels. The compact design and easy mounting make it a practical component in modern industrial control systems.