Further information for Dold 0053718 voltage relay AC50-500V UH AC230V
Technical data
1- / 3-phase
1
Enclosure design
Switch cabinet
Nominal voltage max.
AC 1000 V, DC 900 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9054
Operate delay
Variant
Auxiliary voltage
AC 230 V
Contact equipping
2 changeover contacts
Measuring range
AC 50 - 500 V
Start up delay
Without
Switching delay
0 - 20 s
Approvals and Markings
UKCA, CCC
Variant
Undervoltage relay. De-energized on trip. Time delay at hysteresis value
The voltage relay BA9054/012AC50-500VUHAC230V from Dold is an industrial device for monitoring single-phase AC voltage networks in the range of AC 50 to 500 V. It is used for continuous monitoring of the network voltage to trigger a response when deviations from pre-set limit values occur. The device operates on the principle of residual current and is configured as an under-voltage relay, with the switching delay activated upon reaching the hysteresis value. Adjustment is performed via rotary switches on the front of the device, enabling simple and user-friendly configuration.
Applications
This relay is suitable for monitoring DC and AC voltages in industrial plants as well as in railway applications. It enables early detection of voltage drops to prevent electrical system failures and enhance operational safety. The device is installed in enclosures, with a width of 45 mm allowing compact mounting in standard control panels.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which can be used to control auxiliary circuits or warning systems. The auxiliary voltage is AC 230 V, allowing power supply via standard low-voltage networks. The switching delay is adjustable within a range of 0 to 20 seconds, enabling a delayed response to short-term voltage fluctuations and preventing false tripping. The pickup delay is also integrated to ensure stable response to voltage fluctuations.
Technology Explained Simply
The relay measures the arithmetic mean of the rectified measured voltage. For AC voltages, the device is calibrated to the RMS value, enabling precise measurement even with sinusoidal voltages. The hysteresis depends on the set pickup value, ensuring that feedback only occurs after exceeding a specific threshold. Galvanic isolation between the auxiliary circuit and the measurement circuit ensures safe and interference-free operation. LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED).
Compatibility and Accessories
The device complies with standards IEC/EN 60255-1 and IEC/EN 60947-1 and carries UKCA and CCC certifications. It is designed for a maximum rated voltage of AC 1000 V and DC 900 V, with the measurement range specifically set to AC 50–500 V. The terminal connections are clearly labeled: A1/A2 for auxiliary voltage, e/f for voltage input, and contacts 11/12/14 and 21/22/24 for the two changeover contacts. The measurement frequency can reach up to 5 kHz, enabling use in applications with high frequencies.
Mounting and Installation
Mounting is performed in enclosures using screw fastening. The width of 45 mm corresponds to the standard for DIN rail mounting, allowing easy integration into existing control systems. The terminals are designed for secure and reliable connections, with connection designations directly marked on the device. Adjustment of pickup and hysteresis values is done via rotary switches on the front panel, without requiring additional tools.
Operational Advantages
Precise and reliable voltage monitoring increases operational safety. Early detection of voltage drops enables preventive maintenance and prevents damage to connected devices. LED indicators facilitate diagnostics during operation, and the switching delay reduces the number of false tripping events during short-term disturbances. Galvanic isolation between the measurement and auxiliary circuits ensures high system safety and stability.