Dold 0053625, EAN: 4030641536251

Dold 0053625 voltage relay AC1-10V UH AC/DC24-80V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0053625 voltage relay AC1-10V UH AC/DC24-80V

Lieske Part No. 1312788
Mfg Part No 0053625
EAN-Code 4030641536251
Manufacturer Dold
Here only 335,41 EUR
399,14 EUR incl. VAT

Further information for Dold 0053625 voltage relay AC1-10V UH AC/DC24-80V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Nominal voltage max.AC 1000 V, DC 900 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9054
Operate delayYes
Variant
Auxiliary voltageAC/DC 24 - 80 V
Contact equipping2 changeover contacts
Measuring rangeAC 1 - 10 V
Start up delayWithout
Switching delay0 - 20 s
Approvals and MarkingsUKCA, CCC
VariantOvervoltage relay. Energized on trip. Time delay at setting value
The Dold voltage relay BA9054/010 AC1-10V UH AC/DC24-80V is an industrial voltage relay from the VARIMETER series, designed for monitoring single-phase DC and AC voltage networks. It enables early detection of voltage failures or overvoltages to prevent damage to electrical installations and enhance operational safety. Device settings are adjusted via rotary switches on the front panel, ensuring simple and user-friendly configuration. The device operates on the principle of operating current and switches when the set threshold value is exceeded, with switch delay adjustable between 0 and 20 seconds.

Applications
This relay is suitable for use in industrial and railway applications where reliable voltage monitoring is required. It monitors DC and AC voltages within the measurement range of AC 1 to 10 V. Galvanic isolation between the auxiliary circuit and measurement circuit ensures safe and interference-free measurement. The maximum rated voltage is AC 1000 V and DC 900 V, with devices calibrated for sinusoidal AC voltages based on RMS value. The measurement frequency can reach up to 5 kHz, enabling use in dynamic systems.

Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which can be used to control external circuits. The auxiliary voltage is supplied via AC/DC 24 to 80 V, allowing flexible integration into existing power supply systems. The switch delay of 0 to 20 seconds prevents unwanted switching operations during short-term voltage fluctuations. The pickup delay is also integrated to ensure stable response to voltage fluctuations. LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED), facilitating diagnostics during operation.

Technology Explained Simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, calibration is based on RMS value, enabling precise measurement even with non-sinusoidal voltages. The pickup threshold and hysteresis are adjusted via rotary switches, with hysteresis depending on the set value. The switch delay activates after exceeding the set threshold, allowing delayed switching to ignore short-term voltage spikes. The start-up bypass is not available in this variant, so the device becomes active immediately upon applying auxiliary voltage.

Compatibility and Accessories
The relay complies with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carries UKCA and CCC certifications. It is designed for use in enclosures and has a width of 45 mm, enabling standard mounting on DIN rails. Galvanic isolation between the measurement and auxiliary circuits ensures safe and interference-free operation. The devices can also be used as undervoltage relays, with the switch delay then activating after falling below the hysteresis threshold.

Mounting and Installation
Mounting is performed in enclosures using DIN rail. The connection terminals are clearly labeled: A1 and A2 for auxiliary voltage, e and f for voltage input, and contacts 11, 12, 14 and 21, 22, 24 for the two changeover contacts. Threshold settings are adjusted via rotary switches on the front panel. The LED indicators support commissioning and maintenance by visually signaling the operational status.

Operational Advantages
Precise and reliable voltage monitoring enables early fault detection and preventive maintenance, preventing downtime and increasing productivity. Galvanic isolation and high overload capacity enhance device safety and lifespan. Clear visual indication of operational status via LEDs simplifies diagnostics and maintenance during operation. The device is designed for use in demanding industrial environments and offers high operational safety.
This is an offer of: