| Technical data |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 1 NC contact, 3 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety integrity level according to EN 574 | lll C |
| Safety integrity level according to EN ISO 13851 | lll C |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | BH 5933 |
| Variant |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Nominal voltage | AC 42 V 50/60 Hz |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
The Dold safety relay type BH5933.48 AC42V 50/60Hz is an industrial device for safety-oriented control of machines, particularly in applications with two-hand controls. It is used to enable and interrupt a safety circuit to protect personnel and machines from hazardous movements, for example in metalworking presses. The device is designed as a compact, ready-to-connect two-hand control and allows monitoring of external contactors via a feedback circuit, thereby enabling contact multiplication or amplification.
Applications
This safety relay is intended for use in industrial machines and systems where safe operation via two-hand control is required. Typical application areas include presses, machine tools, and other working machines with hazardous closing movements. Compliance with safety standards is essential here, which is why the device is appropriately certified.
Functions and equipment in detail
The device features a contact configuration with 3 NO contacts and 1 NC contact, enabling flexible integration into existing control systems. The rated voltage is AC 42 V at 50/60 Hz, making it suitable for standard supply voltages in industrial environments. The connection technology uses removable screw terminals, which allow secure and easy connection of cables. The maximum cross-section for connected cables is 2.5 mm², and stranded cables with ferrules according to DIN 46228-1/-2/-3/-4 can also be used.
Technology explained simply
The safety relay operates on the principle of two-hand-controlled safety function, requiring both hands of the operator to activate it, preventing unintentional operation. The integrated monitoring function ensures that the safety circuit is only enabled when both inputs are correctly actuated. The thermal load capacity is specified with a maximum thermal current of 5 A, describing the contact load capacity under continuous operation. The width is 45 mm, enabling compact mounting on standard control panels.
Compatibility and accessories
The device is designed for use with two-hand controls and can be used in combination with external contactors to increase the number of available contacts. The feedback circuit via terminals Y1 and Y2 enables monitoring of external contactors. The approvals include UL-listed C/US, TÜV, and UKCA, confirming compliance with international safety standards.
Mounting and installation
Mounting is done on standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. The connection terminals are designed for cables up to 2.5 mm², and the use of ferrules according to DIN 46228-1/-2/-3/-4 is recommended. Installation must follow the manufacturer’s technical instructions to ensure the safety function.
Advantages in operation
The integrated two-hand control eliminates the need for a separate contactor control, resulting in cost savings. The monitoring function for external contactors increases the reliability of the entire control system. Approvals according to EN ISO 13849-1 (Category 4, Performance Level e), IEC/EN 62061 (SIL 3), and EN ISO 13851 (Safety Level Type III C) guarantee high safety performance. The width of 45 mm allows space-saving installation in existing control systems.
Safety level and approvals
The device meets the requirements for safety functions according to EN ISO 13849-1 (Category 4, PL e), IEC/EN 62061 (SIL 3), and EN ISO 13851 (Type III C). These approvals are essential for use in safety-critical applications. The UL-listed C/US, TÜV, and UKCA approvals confirm compliance with international safety standards.