Further information for Dold 0053381 insulation monitor 380-415V
Technical data
Enclosure design
Distribution board
IMD type
AC
Nominal voltage IT system
AC 0 - 500 V
Response value
5 - 500 kΩ
Response value type
Adjustable
Width
35 mm
Type
IL 5880
Earth fault indicator
Variant
Alarm value
5 - 100 kOhm
Auxiliary voltage
AC 380- 415 V 50 - 400 Hz
Contact equipping
2 x 1 changeover contact
Prewarning value
10 kOhm - 5 MOhm
Approvals and Markings
UKCA, CCC
Variant
Adjustable alarm and pre-warning value. Programmable outputs. De-energized on trip
The insulation monitor IL 5880.12/200 from Dold is a device for monitoring the insulation resistance in ungrounded AC and three-phase networks (IT systems) with a nominal voltage of AC 0 to 500 V. The device operates on the zero-current principle, in which the output relays are not activated in the event of a fault, enabling safe and reliable fault detection. The auxiliary voltage is AC 380 to 415 V at a frequency of 50 to 400 Hz, allowing monitoring of de-energized systems as well. The width is 35 mm, and the device is designed for mounting in installation and industrial distributors according to DIN 43880.
Applications
The IL 5880.12/200 is designed for pure AC and three-phase networks in the frequency range of 10 to 10000 Hz. It is particularly suitable for applications in industry and rail transport, where continuous monitoring of insulation condition is required. The separate supply voltage enables monitoring of de-energized consumers, for example, motor windings of devices that must be switched on in an emergency. A variant of the device is also available for monitoring mobile power generation systems in accordance with DIN VDE 0100-551.
Functions and equipment in detail
The device features two changeover contacts as contact configuration, used for signaling alarm and pre-alarm conditions. The alarm threshold is adjustable and ranges from 5 to 100 kΩ, with a variant available with a threshold of 10 to 500 kΩ. Additionally, an adjustable pre-alarm threshold in the range of 10 kΩ to 5 MΩ is integrated. The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. Indication is provided via LEDs: a green LED indicates operational readiness, a red LED signals an insulation fault, and a yellow LED lights up when the pre-alarm threshold is undershot.
Technology explained simply
The insulation monitor monitors the resistance between the electrical network and earth. If the resistance drops below the set alarm threshold, a fault is signaled. Galvanic isolation between the measurement circuit, auxiliary voltage, and output contacts ensures high safety. The threshold setting is adjusted via a potentiometer on the front of the device, enabling user-friendly adjustment. The integrated reset and test button allows manual resetting and testing of the device. Additionally, external reset and test buttons can be connected.
Compatibility and accessories
The device is available in various designs, with the IL 5880/200 variant designed for installation distributors with bottom-mounted connection terminals. Mounting is either on DIN rail or by screw mounting. The devices comply with the standard IEC/EN 61557-8 and are certified with UKCA and CCC. The connection terminals are intended for connection to the monitored IT network, the protective conductor, and for external test and reset buttons.
Mounting and installation
Mounting is carried out in standard installation distributors or enclosures. The depth is 61 mm, and the connection terminals are arranged at the bottom. The devices are designed for mounting on DIN rail or by screws. The connection designations include A1 and A2 for the monitored network, PE for the protective conductor, PT for the external test button, and LT1/LT2 for external reset buttons or programming.
Advantages in operation
The IL 5880.12/200 provides preventive protection against fires and equipment damage through early detection of insulation faults. The simple adjustment of threshold values and clear LED indication facilitate daily use. Galvanic isolation and the zero-current principle increase the safety and reliability of the device. The programmability of the output relays enables flexible adaptation to different operational requirements.