Further information for Dold 0050437 IK9171.11/030 undervoltage relay 3AC440/254V

Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 500 / 290 V
Output contacts1 C/O contact
Width17,5 mm
TypeIK 9171
Operate delayYes
Variant
Contact equipping1 changeover contact
Nominal voltage3/N AC 440 / 254 V
Response value0,55 - 1,05 Un
Time delay0,5 - 20 s
Approvals and MarkingsUKCA
VariantWith N. NC circuit operation. Settable time delay t1. Settable response value
The Dold undervoltage relay type IK9171.11/030 is an industrial-grade monitoring device for detecting undervoltages in three-phase power networks. It is used for network monitoring and enables automatic switching to a safety power supply or safety lighting in accordance with DIN VDE 0100-710 and DIN VDE 0108. The device operates on the stand-by current principle, whereby the output relay is not activated in the event of a fault, ensuring safe and reliable fault detection. The width is 17.5 mm, and it is designed for installation in installation distributors according to DIN 43 880, with connection terminals located at the bottom (I-type construction). The nominal voltage is 3/N AC 440 / 254 V, and the device can also be connected single-phase by connecting terminals L1, L2, and L3. The maximum nominal voltage is 3/N AC 500 / 290 V.

Applications
This relay is used in industrial and commercial facilities where continuous power supply is critical. It monitors three-phase networks for undervoltages and can trigger a safety function upon detection of a fault, such as phase loss or voltage drop. Typical applications include securing emergency lighting, safety systems, or controlling switching to backup power supplies. The variant with time delay t1 (0.5–20 s) is particularly used in unstable networks to avoid immediate shutdown during short-term voltage dips. The time delay t1 is only effective if the phase voltage L1-N (for IK/SK 9171) is at least 0.5 Un.

Functions and Equipment in Detail
The device features an adjustable pickup value in the range of 0.55 to 1.05 Un, allowing flexible adaptation to various network conditions. The hysteresis is approximately 4 %, ensuring stable switching behavior during voltage fluctuations. The contact configuration includes one changeover contact (1 C/O contact), suitable for controlling auxiliary functions or safety circuits. A yellow LED indicates the contact position: when the output relay is activated (contacts 11-14 closed), the LED lights up. Phase sequence is arbitrary, simplifying installation. The device operates without auxiliary voltage, simplifying installation and maintenance.

Technology Explained Simply
The relay measures the arithmetic mean of each of the three phases against the neutral conductor (N). For variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). When a voltage drop falls below the set pickup value, the output contact opens, enabling control of an external switch or safety function. The time delay t1 ensures that the device initially enters the good state upon power-up, even if a fault is present. The fault state is only activated after the delay time has elapsed, preventing false alarms during short-term voltage dips.

Compatibility and Accessories
The device is suitable for single-phase and three-phase connections and can be used in 3/N AC 440 / 254 V networks as well as in other voltage ranges up to 3/N AC 500 / 290 V. It is equipped with a neutral conductor connection and complies with the standard IEC/EN 60255-1. UKCA approval is granted.

Mounting and Installation
Mounting is performed in installation distributors according to DIN 43 880. The depth is 59 mm, and the connection terminals are located at the bottom. The frequency range is between 45 and 65 Hz. The devices are designed for continuous overload capacity of 1.15 Un. The nominal consumption is approximately 6 VA for IK/SK 9171.11.

Advantages in Operation
The relay provides reliable network monitoring without auxiliary voltage, simplifying installation. Adjustable parameters such as pickup value and time delay allow flexible adaptation to different requirements. The LED indicator facilitates diagnosis and maintenance. The stand-by current principle ensures safe fault detection, as the output relay is not activated in the event of a fault. The construction is compact (17.5 mm width) and fits in standard distributor enclosures.