Further information for Dold 0050077 safety relay BH5928.92 AC/DC24V 0,1-1S
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts, 1 NC contact instantaneous, 3 NO contacts off delay
Nominal voltage
AC/DC 24 V
Time range
0,1 - 1 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold safety relay BH5928.92 is an emergency stop module with adjustable time delay, designed for use in safety-critical systems. It operates at a nominal voltage of AC/DC 24 V and offers a time range from 0.1 to 1 second. The device is designed for the protection of personnel and machinery, particularly in emergency stop circuits, where a stop category 1 can be achieved. It is also suitable for monitoring sliding safety guards and can be used as a safety door monitor.
Applications
This safety relay is intended for use in industrial systems where safe shutdown is required in hazardous situations. It is used in machine controls to ensure safe machine shutdown when an emergency stop button is activated or when a safety door is opened. The function as a safety door monitor enables monitoring of access areas, where the device responds to the opening of a safety door and shuts down the machine if the door is opened. The application is in environments where safety requirements according to EN ISO 13849-1 and IEC/EN 62061 must be met.
Functions and Equipment in Detail
The device features contact configuration with 2 NO contacts, 1 NC contact immediately, and 3 NO contacts with delayed reset. The delayed reset contacts enable controlled shutdown over an adjustable time range of 0.1 to 1 second. The output contacts are rated for a maximum thermal current of 5 A. The connection technology uses removable screw terminals, enabling flexible and secure connections. The terminals are suitable for wires with 2 x 1.5 mm² with ferrule and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² with ferrule DIN 46 228-1/-2/-3.
Technology Explained Simply
The safety relay operates on the principle of redundant safety monitoring. It can be operated in a 1- or 2-channel configuration, with the 2-channel version offering a higher safety level. Cross-circuit detection at the single button (terminals S33–S34) detects faults in the control circuit, such as short circuits or open lines. The status indicator for the delayed reset timing circuit, along with LED indicators for power supply, channel 1/2, and time delay, enable visual monitoring of the operating status. Activation occurs either via a single button at S33–S34 or via an automatic activation function with a bridge at S13–S14.
Compatibility and Accessories
The device is designed for use in safety systems that meet the requirements of standards EN ISO 13849-1 and IEC/EN 62061. It has a width of 45 mm and can be mounted in standard control panels. Certifications include UL-listed C/US, TÜV, and CCC. The SIL claim limit (SIL CL) is 3 according to IEC/EN 62061, corresponding to safety integrity level SIL 3. The Performance Level (PL) e and Category 4 according to EN ISO 13849-1 guarantee high safety performance.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. Wiring is done according to the circuit diagrams in the datasheet, taking into account the terminal assignment and connection options for the emergency stop function and cross-circuit detection. The LED indicators support commissioning and fault diagnosis.
Advantages in Operation
The safety relay offers high reliability through redundant safety functions and clear status indication. The adjustable time delay enables tailored shutdown, increasing operational safety. Cross-circuit detection prevents false alarms and ensures the integrity of the control circuit. The connection terminals are suitable for various wire cross-sections, increasing flexibility during installation. The certifications and markings guarantee compliance with international safety standards.