| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 3 NO contacts, 3 NO contacts delayed |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | BH 5928 |
| Cross fault detection | |
| Suited as safety gate monitor | |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact instantaneous, 3 NO contacts off delay |
| Nominal voltage | AC/DC 24 V |
| Time range | 1 - 10 s |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With adjustable time delay |