Further information for Dold 0045456 BD5935.48DC24V emergency stop module
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
1 NC contact, 3 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
45 mm
Type
BD 5935
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 1 NC contact
Nominal voltage
DC 24 V
Approvals and Markings
TÜV, UKCA, CCC
The Dold BD5935.48DC24V is a not-out module of the SAFEMASTER series, designed for the safe interruption of safety circuits in industrial applications. It is particularly used for protecting personnel and machinery in systems with emergency stop buttons and safety doors. The device is designed for use in safety-oriented installations and meets the requirements for high safety integrity. The nominal voltage is DC 24 V, and the width of 45 mm allows for compact mounting in standard enclosures.
Applications
The module is used in installations where a safe and reliable interruption of the circuit is required in an emergency. Typical applications include machines with safety doors, where opening the door automatically stops operation, or emergency stop functions activated via a button. The function as a safety door monitor is explicitly intended, enabling the device to be used in safety-critical machine installations. The cross-short detection ensures that a short circuit between channels is detected and the safety state is maintained.
Functions and equipment in detail
The device features contact configuration with 3 closers and 1 opener, enabling flexible wiring in safety circuits. The contacts are gold-plated, ensuring reliable switching even under low loads, such as signals for PLC systems. The connection technology uses removable screw terminals, allowing for quick replacement of the device without complete rewiring. The connection cross-sections support up to 2 x 2.5 mm² stranded wire with ferrules according to DIN 46228-1/-2/-3/-4, providing broad compatibility with common cables. An operating status indicator with LEDs for channel 1 and 2 shows the current status of the module.
Technology explained clearly
The module is designed for single- or dual-channel wiring, making it suitable for use in both simple and redundant safety systems. The safety functions are certified according to international standards: it complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest requirement for safety functions in mechanical installations. Additionally, it meets the requirements for SIL 3 according to IEC/EN 62061 and SIL 3 according to IEC/EN 61508, ensuring high safety integrity. The maximum thermal current is 10 A, defining the contact load capacity. An integrated overvoltage and short-circuit protection protects the device and connected components from damage.
Compatibility and accessories
The module is designed for use in safety-oriented installations and can be combined with other components of the SAFEMASTER program. The certifications TÜV, UKCA, CCC and recognition by UL-Recognized ensure usability in various markets. The connection technology with removable terminals allows for easy integration into existing control systems. It is designed for use in enclosures with a standard width of 45 mm.
Mounting and installation
Mounting is performed in standard enclosures with a width of 45 mm. The removable screw terminals simplify installation and maintenance, as the device can be replaced without removing the wiring. Wiring is carried out according to the circuit diagrams in the datasheet, supporting connection cross-sections up to 2.5 mm² stranded wire with ferrules. Device programming is done via the specified settings described in the datasheet.
Advantages in operation
The combination of high safety integrity, flexible contact configuration, and quick replacement via removable terminals makes the module a reliable solution in safety-critical installations. The integrated cross-short detection and operating status indicator enhance diagnostic capability during operation. Certifications according to international standards enable use in various regions and industries. The use in emergency stop and safety door applications is supported by the specific design of the device.