Dold 0045377, EAN: 4030641453770

Dold 0045377 MK9151.11 2-450K-OHM AC24V level relay

Dold 0045377 MK9151.11 2-450K-OHM AC24V level relay

Lieske Part No. 1001938
Mfg Part No 0045377
EAN-Code 4030641453770
Manufacturer Dold
Here only 164,26 EUR
195,47 EUR incl. VAT

Further information for Dold 0045377 MK9151.11 2-450K-OHM AC24V level relay

Technical data
ClassificationFüllstandsüberwachung
Enclosure designSwitch cabinet
Measuring range max.450 kΩ
Output contacts1 C/O contact
Width22,5 mm
TypeMK 9151
Operate delayYes
Variant
Auxiliary voltageAC 24 V
Contact equipping1 changeover contact
Response value2 - 450 kOhm
VariantTime delay, when level rises over and drops under setting value
The Dold level relay MK9151.11 2-450K-OHM AC24V is an industrial device for monitoring the fill level of conductive liquids and powders. It is used for continuous monitoring of maximum and minimum fill levels, provides protection against overfilling and dry running, and enables control of filling processes in tanks. The device is designed for use in enclosures and has a width of 22.5 mm, making it suitable for standard control panels.

Applications
This relay is used in systems where precise monitoring of liquid level is required, for example in water supply, wastewater treatment, chemical industry, or food processing. It is suitable for 1-point and 2-point level control, where 1-point control is intended for overflow or dry-running protection with free inflow or outflow. In 2-point control, the level is maintained between a minimum and maximum value, with electrodes MIN, MAX and COM connected. Applications also include monitoring the mixing ratio of conductive liquids and general resistance monitoring tasks, such as detecting limit temperatures with PTC resistors.

Functions and Equipment in Detail
The device features an adjustable trigger value in the range of 2 to 450 kΩ, allowing differentiation between liquid and foam. The trigger and reset delay can be adjusted between 0.2 and 20 seconds, enabling controlled response to short-term level changes. Programming is done for either the operating current principle (without bridge, output relay activated in case of fault) or the resting current principle (bridge X1-X2 or X1-COM, output relay not activated in case of fault). The output contacts consist of a changeover contact, which can be used to control pumps, solenoid valves or other loads.

Technology Explained Simply
The relay's measuring circuit is galvanically isolated from the mains, ensuring high immunity to interference. The maximum cable length to the electrodes is 3000 meters, with the actual length depending on the set resistance range. The measuring voltage is generated internally (approx. AC 10 V) and the measuring current is approximately AC 1.5 mA for a measuring range of 2 to 450 kΩ. The operating voltage is AC 24 V, although the device is also available for other auxiliary voltages from AC 24 to 415 V or DC 24 V. Operational readiness is indicated by a green LED, and contact status by a yellow LED.

Compatibility and Accessories
The relay is equipped with three electrode connection terminals, suitable for use with standard market-available electrodes. The reference electrode is typically mounted at the lowest point of the tank and connected to terminal COM. In conductive tanks, the tank itself can serve as the reference electrode. The device is also available in a version with a tamper-proof transparent cover and secure separation according to IEC/EN 61140 and IEC/EN 60947-1.

Mounting and Installation
Mounting is done in an enclosure, with the width of 22.5 mm ensuring compatibility with standard control panels. The connection terminals are clearly labeled: A1 (+/L), A2 (-/N), COM (reference electrode), MIN/MAX (limit electrodes), X1 (control input), X2 (control output), and the changeover contacts 11, 12, 14 and 21, 22, 24. The electrodes are connected according to the desired control mode (1-point or 2-point).

Advantages in Operation
The relay offers high reliability due to galvanic isolation of the measuring circuit and a wide adjustable trigger value range. The adjustable delay time prevents false alarms caused by short-term level fluctuations. The clear LED indication allows for quick status checks. The maximum cable length of 3000 meters allows flexible installation of electrodes, even in large tanks or over long distances.