Dold 0042021, EAN: 4030641420215

Dold 0042021 undervoltage relay IL9071.12 3/N AC400/230V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0042021 undervoltage relay IL9071.12 3/N AC400/230V

Lieske Part No. 798298
Mfg Part No 0042021
EAN-Code 4030641420215
Manufacturer Dold
Here only 253,15 EUR
301,25 EUR incl. VAT

Further information for Dold 0042021 undervoltage relay IL9071.12 3/N AC400/230V

Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 500 / 290 V
Output contacts2 C/O contacts
Width35 mm
TypeIL 9071
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3/N AC 400 / 230 V
Response value0,7 Un 4%
Time delaywithout
Approvals and MarkingsCCC
VariantWith neutral connection. Without asymmetry detection. Without neutral conductor monitoring. Without time delay
The Dold undervoltage relay IL9071.12 is a device for monitoring alternating current and three-phase networks for undervoltage, phase failure, and loss of the neutral conductor. It is designed for use in industrial and installation distributor enclosures and complies with the standard IEC/EN 60255-1. The relay monitors three-phase networks with neutral conductor (3/N AC 400/230 V) and can also be connected single-phase, in which case terminals L1, L2, and L3 must be bridged. The nominal voltage is 3/N AC 400/230 V, with the device being overloadable up to 3/N AC 500/290 V. The pickup value is fixed at 0.7 times nominal voltage (Un) with a hysteresis of 4 %. In the event of undervoltage or other faults, the output relay is not activated (standby current principle), thereby increasing safety. The operating frequency is 50/60 Hz, with a frequency range of 45 to 65 Hz. The input current consumption is approximately 1.5 mA at L1-N and L2-N, and approximately 25 mA at L3-N. The nominal power consumption is approximately 6 VA (L3-N). The operating voltage range extends from 0.7 to 1.1 times nominal voltage.

Applications
This relay is suitable for monitoring three-phase networks in industrial plants, buildings, and installation distributor enclosures. It serves for early detection of network disturbances such as undervoltage, phase failure, or neutral conductor break, to prevent damage to connected devices. Monitoring is particularly important in installations where single-phase consumers are connected to the neutral conductor, as a neutral conductor break can cause dangerous voltage imbalances. Applications also include switching on safety lighting in accordance with DIN VDE 0108. The device is available for use in rooms according to DIN VDE 0100-710 (medically used rooms), which is an optional variant.

Functions and Equipment in Detail
The IL9071.12 features two changeover contacts (2 C/O contacts) with a contact material of AgNi. The switching voltage is AC 250 V. The switching capacity according to AC 15 (IEC/EN 60947-5-1) is 3 A / AC 230 V for closing contacts and 2 A / AC 230 V for opening contacts. The electrical life expectancy is approximately 500,000 switching cycles at 1 A and AC 230 V. The output contacts are designed such that they are not activated in the event of a fault (standby current principle), providing higher safety. The LED indicator lights green when the network is fault-free (contacts 11-14 and 21-24 closed). The indicator serves as a visual confirmation of the operating status. The device design is intended for installation distributors, with a width of 35 mm and a depth of 61 mm. The connection terminals are located at the bottom, enabling installation in distributor enclosures according to DIN 43880. The devices are equipped with safe separation between the measuring circuit and contacts in accordance with IEC/EN 61140 and IEC/EN 60947-1.

Technology Explained Simply
The relay measures voltage in a three-phase network with neutral conductor and detects deviations from nominal voltage. If undervoltage occurs below 0.7 times nominal voltage (with 4 % hysteresis), the output relay is not activated, meaning the contacts remain open in the event of a fault. The LED indicator visually signals the operating status. Phase sequence is arbitrary, allowing adaptation to various network configurations. The devices are suitable for use in both single-phase and three-phase networks, with terminals L1, L2, and L3 to be bridged in single-phase connection. Overload capability is AC 440 V at all measuring inputs for at least one hour.

Compatibility and Accessories
The IL9071.12 is designed for use in installation and industrial distributor enclosures. It is compatible with network voltages of 3/N AC 400/230 V and can also be used at other voltages in the range of 3/N AC 100/58 V to 500/290 V. The devices are available in two designs: IL 9071 (61 mm depth, terminals at bottom) and SL 9071 (98 mm depth, terminals at top). The SL variant is intended for enclosures with mounting plate and cable duct. The devices are available according to DIN VDE 0100-710 for medically used rooms, which is an optional variant. The devices are equipped with an LED indicator that visually signals the operating status.

Mounting and Installation
Mounting is carried out in installation or industrial distributor enclosures according to DIN 43880. The width is 35 mm, the depth is 61 mm. The connection terminals are located at the bottom. In single-phase connection, terminals L1, L2, and L3 must be bridged. Phase sequence is arbitrary, enabling flexible installation. The devices are designed for use in distributor enclosures, with the SL variant intended for enclosures with mounting plate and cable duct.

Advantages in Operation
The IL9071.12 enables early detection of network disturbances, allowing preventive maintenance and preventing damage to connected devices. Operational safety is increased, as the device does not activate the output relay in the event of faults (standby current principle). The LED indicator visually signals the operating status. Phase sequence is arbitrary, enabling flexible installation. The devices are suitable for use in both single-phase and three-phase networks, with terminals L1, L2, and L3 to be bridged in single-phase connection. Overload capability is AC 440 V at all measuring inputs for at least one hour.