Dold 0039122, EAN: 4030641391225

Dold 0039122 undervoltage relay BA9043/003 3AC50/60Hz 400V 0,5-10S

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0039122 undervoltage relay BA9043/003 3AC50/60Hz 400V 0,5-10S

Lieske Part No. 916050
Mfg Part No 0039122
EAN-Code 4030641391225
Manufacturer Dold
Here only 302,01 EUR
359,39 EUR incl. VAT

Further information for Dold 0039122 undervoltage relay BA9043/003 3AC50/60Hz 400V 0,5-10S

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 400 V
Time delay0,5 - 10 s
Approvals and MarkingsUKCA, CCC
VariantFor 3p3w systems. With adjustable time delay
The Dold undervoltage relay BA9043/003 is a 3-phase monitoring device for three-phase power networks without a neutral conductor. It is designed for continuous monitoring of the supply voltage and disconnects connected loads in case of undervoltage or voltage loss to prevent damage to electrical equipment. The device is rated for nominal voltages of 3AC 400 V and supports frequencies from 50 to 400 Hz. Measurement is performed via arithmetic mean calculation, where phases L1 and L2 are measured against L3, as no neutral conductor connection is available. The device settings are adjusted via rotary potentiometers on the front panel, allowing the pickup and dropout values to be continuously adjusted between 0.85 and 1.05 of the nominal voltage, and the hysteresis between 0.75 and 0.95 of the pickup value.

Applications
This relay is designed for use in industrial and railway applications where reliable voltage monitoring is required. It is particularly suitable for systems that depend on stable power supply, such as production plants, conveyor systems, or vehicle drives.

Functions and Features in Detail
The device features two changeover contacts, which can be used for protecting loads or signaling faults. The contact configuration allows control of auxiliary relays, warning lights, or disconnection mechanisms. The output relays operate on the rest current principle, meaning they are inactive in the normal state and only energized in the event of a fault. This increases safety and reduces false alarm rates. Two LED indicators signal the operating status: a red LED lights up when operating voltage is present, and a green LED indicates activation of the output relay.

Technology Explained Simply
Voltage monitoring is performed by measuring individual phases against the reference phase (L3), thereby determining the arithmetic mean of the supply voltage. The time delay is adjustable and ranges from 0.5 to 10 seconds. This delay is only effective if the voltage is at least 60 % of the nominal voltage. Below 40 % of the nominal voltage, disconnection occurs immediately. The adjustable time delay allows adaptation to the specific requirements of the installation, enabling short-term voltage dips to be ignored and responding only to sustained disturbances.

Compatibility and Accessories
The relay is suitable for networks with or without a neutral conductor, with the BA9043/003 variant specifically designed for systems without a neutral conductor. It complies with standards IEC/EN 60255-1 and is certified with UKCA and CCC approvals. The devices are designed for use in enclosures and mount on a DIN rail. The width is 45 mm, enabling compact installation in standard control panels. The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical life exceeds 30 million switching operations.

Mounting and Installation
Mounting is done on a DIN rail according to IEC/EN 60715. The terminal connections are rated for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Fixing is achieved using M3.5 plus-minus screws with self-lifting clips. The required stripping length is 10 mm, and the tightening torque for the screws is 0.8 Nm. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C. The maximum operating altitude is 2000 m above sea level.

Operational Advantages
Thanks to the continuous adjustability of pickup and dropout values as well as time delay, the device can be optimally adapted to the specific requirements of each installation. The LED indicators enable quick fault localization. The immunity to harmonics ensures stable operation even in networks with high harmonic content. The ability to operate without auxiliary power reduces installation complexity and increases reliability. Compliance with the IEC/EN 60255-1 standard ensures the quality and safety of the device.