Further information for Dold 0037332 BD5987.02DC24V emergency stop module
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Screw terminals
Output contacts max.
2 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
45 mm
Type
BD 5987
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts
Nominal voltage
DC 24 V
Approvals and Markings
TÜV
The Dold safety relay BD5987.02DC24V is a not-out module for use in safety-oriented systems. It is designed for the safe interruption of circuits, particularly in applications with emergency stop buttons and safety doors. The device is designed as a safety relay and complies with the requirements of standards EN ISO 13849-1 and IEC/EN 62061. It is designed for use in industrial environments where the safety of personnel and machines is paramount.
Applications
The BD5987.02DC24V is intended for use in systems with emergency stop functions, for example in manufacturing industry, on machines with safety doors, or in elevator installations according to EN 81-20. It can be used as an electronic safety circuit to replace a safety switch according to EN 81-20, section 5.11.2.2. The function as a safety door monitor is explicitly confirmed, enabling integration into systems with access protection.
Functions and equipment in detail
The device features 2 normally closed contacts as output contacts, designed for a rated voltage of DC 24 V. The contacts are gold-plated, ensuring reliable switching even under low loads, for example for signals to a PLC. Cross-short detection in the emergency stop control circuit is activated, enabling detection of a short circuit between channels and ensuring the safety function. Connection is made via screw terminals, suitable for wires with cross-sections up to 2.5 mm², with the option of using sleeves and plastic collars according to DIN 46 228-1/-2/-3/-4.
Technology explained simply
The safety relay operates on the principle of safety-oriented interruption. When an emergency stop button is triggered or a safety door is opened, the circuit is interrupted to safely shut down the machine. The Cat. 4 / PL e according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061 guarantee a high level of safety performance. The thermal current Ith max. is 10 A, defining the contact load capacity. The width of 45 mm allows compact mounting in standard control panels.
Compatibility and accessories
The device is designed for 1- or 2-channel wiring, enabling flexible use in different safety configurations. It is equipped with LED indicators for channel 1, channel 2, and power supply, visually displaying the operating status. The certifications TÜV and UL-Recognized confirm compliance with international safety standards. The application as a safety door monitor is explicitly intended, enabling use in systems with access protection.
Mounting and installation
Mounting is carried out in standard control panels with a width of 45 mm. The screw terminals allow secure and easy connection of wires. The connection terminals are designed for wires up to 2.5 mm², with the recommended use of sleeves and plastic collars according to DIN 46 228-1/-2/-3/-4. Installation must follow the manufacturer’s technical instructions to ensure the safety function.
Advantages in operation
The BD5987.02DC24V provides safe interruption of circuits with high reliability. The integrated cross-short detection prevents malfunctions due to short circuits. The LED indicators enable quick diagnosis of the operating status. The gold-plated contacts ensure long service life and reliable switching, even under low loads. The TÜV and UL-Recognized certifications ensure compliance with international safety standards.