Dold 0028423 BA9043/001 under-voltage relay 100V

Dold 0028423 BA9043/001 under-voltage relay 100V

Lieske Part No. 1153814
Mfg Part No 0028423
EAN-Code 4030641284237
Manufacturer Dold
Here only 262,20 EUR
312,02 EUR incl. VAT

Further information for Dold 0028423 BA9043/001 under-voltage relay 100V

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 100 V
Time delaywithout
Approvals and MarkingsUKCA, CCC
VariantFor 3p3w systems
The Dold undervoltage relay BA9043/001 is a 3-phase monitoring device for three-phase AC networks without a neutral conductor. It is designed for continuous monitoring of the network voltage and disconnects connected loads in case of undervoltage to prevent damage to electrical devices. The device is rated for nominal voltages of 3AC 100 V and can be used in networks with frequencies from 50 to 400 Hz. Measurement is performed via arithmetic mean value calculation, where phases L1 and L2 are measured against L3, as no neutral conductor connection is available. The device settings are adjusted via rotary potentiometers on the front panel, allowing the pickup and dropout values to be continuously adjusted between 0.85 and 1.05 of the nominal voltage, as well as a dropout ratio between 0.75 and 0.95 of the pickup value. The pickup delay is active, however, no time delay is present in this variant.

Applications
This relay is suitable for industrial applications as well as railway applications. It monitors 3-phase AC networks and is mounted in enclosures. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The devices comply with IEC/EN 60255-1 standards and meet the requirements of overvoltage category III.

Functions and Equipment in Detail
The device features two changeover contacts as output contacts, designed for switching operations with a thermal current of up to 6 A per contact. The switching capacities are 2 A/AC 230 V for make contacts and 1 A/AC 230 V for break contacts according to IEC/EN 60947-5-1. The electrical life expectancy is at least 200,000 switching operations at 3 A/AC 230 V and cos ϕ = 1. The mechanical life expectancy exceeds 30 million switching operations. The nominal power consumption is 4 VA.

Technology Explained Simply
The arithmetic mean value measurement enables precise voltage monitoring by averaging the voltage values of the individual phases. In case of undervoltage below the set pickup value, the relay disconnects the output contacts. The LED indicators signal operational readiness (red LED) and contact position (green LED). The device is insensitive to harmonics, meaning it operates reliably even during network disturbances caused by harmonics. The pickup delay ensures that short-term voltage dips do not trigger false alarms.

Compatibility and Accessories
The relay is designed for networks without a neutral conductor and can be used in 3p3w systems. It is certified with UKCA and CCC approvals. Mounting is done on a DIN rail in accordance with IEC/EN 60715. The terminals are designed for 2 x 2.5 mm² solid or 2 x 1.5 mm² flexible conductors with shrink tubing. Fixing is achieved using M3.5 plus-minus screws with self-lifting clips. Dimensions are 45 mm width, 73 mm height, and 132 mm depth.

Mounting and Installation
Installation is carried out in an enclosure on a DIN rail. The connection terminals are intended for connection to the phases L1, L2, and L3 to be monitored. The output contacts (11, 12, 14 and 21, 22, 24) are connected to the loads to be protected. Adjustment of the pickup and dropout values is done via the rotary potentiometers on the front panel. The devices are designed for continuous operation and do not require additional auxiliary voltage.

Advantages in Operation
Preventive maintenance is supported by continuous monitoring of the network voltage. Rapid fault localization enables efficient troubleshooting. The high service life and reliability of the relay contribute to increased productivity. The LED indicators facilitate visual monitoring of the operating status. Insensitivity to harmonics ensures stable operation even in electrically stressed networks. Simple operation via rotary potentiometers reduces installation and maintenance time.