Further information for Dold 0027490 undervoltage relay 220V 0.5-10S
Technical data
1- / 3-phase
3
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
3/N AC 690 / 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9043
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
3AC 220 V
Time delay
0,5 - 10 s
Approvals and Markings
UKCA, CCC
Variant
For 3p3w systems. With adjustable time delay
The undervoltage relay BA9043/0033AC50/60HZ220V0,5-10S from Dold is a 3-phase monitoring device for three-phase AC networks without a neutral conductor. It is designed for continuous monitoring of network voltage and de-energizes output contacts in case of undervoltage, protecting downstream devices or systems from damage. The device settings are adjusted via rotary potentiometers on the front panel, enabling user-friendly and precise adjustment of pickup and dropout values. The device operates on the standby current principle, where the output relay is not activated in the event of a fault, ensuring a safe disconnection.
Applications
This relay is designed for use in industrial and railway applications, where reliable voltage monitoring of 3-phase AC networks is required. It is particularly suitable for networks with frequencies between 50 and 400 Hz and is rated for nominal voltages of 3AC 220 V. The maximum nominal voltage is 3/N AC 690/400 V, and the device can be operated continuously under overload conditions up to 1.2 times the nominal voltage. The harmonic insensitivity makes it robust against network disturbances caused by nonlinear loads.
Functions and Equipment in Detail
The device monitors voltage via arithmetic mean value measurement. In the BA9043/003 variant, designed for networks without a neutral conductor, phases L1 and L2 are measured against L3. The pickup delay is adjustable and ranges from 0.5 to 10 seconds. This delay is only effective if the voltage is at least 60 % of the nominal voltage. Below 40 % of the nominal voltage, disconnection occurs immediately. The hysteresis (dropout ratio) is also adjustable and ranges between 75 % and 95 % of the pickup value, ensuring stable switching behavior.
Technology Explained Simply
Power supply is directly from the monitored network. The LED indicators signal the operating status: a red LED lights up when operating voltage is present, and a green LED indicates that the output relay is activated. The contact configuration includes 2 changeover contacts, rated for switching operations with a switching capacity according to AC 15 (make: 2 A / AC 230 V) and DC 13 (break: 1 A / DC 24 V). The mechanical life expectancy exceeds 30 million switching cycles, while the electrical life expectancy is 200,000 switching cycles at 3 A and AC 230 V.
Compatibility and Accessories
The device is designed for three-phase networks without a neutral conductor and complies with the standard IEC/EN 60255-1. It is suitable for operation at altitudes up to 2000 m above sea level and can be operated in a temperature range from -20 °C to +60 °C. The housing design is intended for installation in enclosures, with a width of 45 mm. Mounting is done on a DIN rail according to IEC/EN 60715. The terminals are designed for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with shrink tubing, secured using M3.5 plus-minus screws with self-lifting clips.
Mounting and Installation
Mounting is done on a DIN rail inside the enclosure. The connection terminals are designed for connection to phases L1, L2, L3 (without neutral conductor) as well as for output contacts (11, 12, 14 and 21, 22, 24). Cable cross-sections and tightening torques (0.8 Nm) are specified in the datasheet. Adjustment of pickup and dropout values as well as time delay is done via the rotary potentiometers on the front panel. The devices are designed for continuous operation and have a nominal power consumption of 4 VA.
Operational Advantages
Through preventive maintenance and faster fault localization, productivity is increased. The clear indication of operating states via LEDs enables quick diagnosis. The harmonic insensitivity and surge voltage resistance (overvoltage category III) ensure high reliability in industrial environments. Compliance with the standard IEC/EN 60255-1 as well as UKCA and CCC certifications guarantee conformity with European and Chinese safety requirements.