Dold 0000877, EAN: 4030641008772

Dold 0000877 overcurrent relay AI 838 AC50/60Hz 8-16A

Dold 0000877 overcurrent relay AI 838 AC50/60Hz 8-16A

Lieske Part No. 100226
Mfg Part No 0000877
EAN-Code 4030641008772
Manufacturer Dold
Here only 286,96 EUR
341,48 EUR incl. VAT

Further information for Dold 0000877 overcurrent relay AI 838 AC50/60Hz 8-16A

Technical data
1- / 3-phase1
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Output contacts1 C/O contact
Width45 mm
TypeAI 838
Variant
Contact equipping1 changeover contact
Measuring rangeAC 50/60 Hz 8 - 16 A
The Dold overcurrent relay AI 838 AC50/60HZ 8-16A is a single-phase measuring relay for current monitoring in industrial enclosures. It is designed for continuous monitoring of alternating current circuits in the range of 8 to 16 A at 50/60 Hz and responds as soon as the set pickup value is exceeded. The relay scale is adjusted to the pickup value, so the device activates when this value is reached. It returns to its resting position as soon as the current falls below the drop-out value, which is calculated by multiplying the pickup value by the drop-out ratio (hysteresis). This function enables reliable and drop-out-stable signaling in case of overloads.

Applications
This relay is suitable for use in industrial systems such as machine controls, drive technology, or power distribution systems. It is mounted in enclosures and serves protective and monitoring functions, for example, in monitoring motors, transformers, or other electrical consumers. The direct measurement in the range of 8 to 16 A makes it particularly suitable for applications with medium current levels.

Functions and Equipment in Detail
The device features an adjustable pickup value screw that can be set continuously. Adjustment is performed from the inside, ensuring precise and secure calibration. The contact configuration includes one changeover contact (1 C/O contact), which is used for signal transmission to external devices such as alarm systems or controls. The switching delay is approximately 100 ms, which allows suppression of short current surges. The electrical life expectancy is up to 5 million switching operations, indicating high operational reliability.

Technology Explained Simply
The relay operates without auxiliary voltage, meaning it is directly powered from the monitored circuit. The measurement range shift due to different lead lengths is described in the datasheet, with values based on a lead having a resistance of approximately 0.5 mΩ. Internal resistances vary depending on the measurement range and are in the range of 0.00822 Ω for the 8–16 A range. Repeatability is ≤ ±2 % for alternating current and ≤15 % for direct current. Overload capability is defined for continuous operation up to 12 A at a factor of 1.0 x scale end value and for 16 A at 1.2 x scale end value. For short-term operation (1 second), the relay can be loaded up to 2.0 x scale end value.

Compatibility and Accessories
For currents above 16 A, the measurement range can be extended by inserting a current transformer. For example, a current transformer with a secondary rated current of 5 A (e.g., type KSW 73 from Ritz Instrument Transformers GmbH) can be used. For direct current applications, a parallel connection of a shunt resistor is required. The rated power consumption is below 18 VA for alternating current. Rated current values for shunts are listed in the datasheet, with specifications applying to a shunt of 150 mV.

Mounting and Installation
The device is designed for installation in enclosures and has a width of 45 mm. Mounting is done in standard switchboards with appropriate fastening options. The connection terminals are clearly labeled: i, k for the current measurement input and 11, 12, 14 for the changeover contact. Installation must follow the technical specifications in the datasheet, taking into account lead length and resistance.

Operational Advantages
The relay offers high operational reliability through the adjustable pickup value screw and stable hysteresis. Its ability to operate without auxiliary voltage reduces installation complexity. The long electrical life and high switching durability make it a reliable component in industrial applications. Compliance with the standard IEC/EN 60255-1 ensures adherence to international standards for measuring instruments.

Approvals and Markings
The device complies with the standard IEC/EN 60255-1. Approvals and markings are listed in the datasheet, with information based on the technical status at the time of publication. Technical improvements and modifications may be made at any time.

Functional Safety
Functional safety is ensured by the adjustable pickup value screw and stable hysteresis. The ability to operate without auxiliary voltage reduces installation complexity. The long electrical life and high switching durability make it a reliable component in industrial applications.