| Technical data |
| 1- / 3-phase | 1 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Output contacts | 1 C/O contact |
| Width | 45 mm |
| Type | AI 838 |
| Variant |
| Contact equipping | 1 changeover contact |
| Measuring range | AC 50/60 Hz 0,5 - 1 A |
The overcurrent relay AI 838 from Dold is a single-phase measuring relay designed for use in enclosures, intended for monitoring alternating current circuits in the AC 50/60 Hz range with a measuring range of 0.5 to 1 A. It is used to detect currents exceeding the set pickup value and triggers a switching operation via an integrated changeover contact when the threshold is exceeded. The relay's scale is adjusted to the pickup value, so the relay activates as soon as the current exceeds the set value. It returns to its resting position when the current falls below the drop-out value, which is determined by multiplying the pickup value by the drop-out ratio (hysteresis). The hysteresis is approximately 0.8 at the beginning of the scale and approximately 0.9 in the middle or at the end of the scale for alternating current. For direct current with residual ripple below 5 %, the hysteresis is approximately 0.6 at the beginning of the scale and approximately 0.7 in the middle or at the end. The pickup value is adjusted continuously and internally on the device. The switching delay is approximately 100 ms, with longer delays achievable by connecting an external time or delay relay in series.
Applications
The AI 838 is intended for use in industrial and technical installations where precise current monitoring is required. It is suitable, for example, for monitoring motors, transformer windings, heating circuits, or other loads where an unexpected current increase may indicate a fault or overload. The enclosure design and width of 45 mm allow for easy mounting in standard control panels. The device is compliant with IEC/EN 60255-1 and designed for use in electrical installations with a rated voltage up to 230 V AC.
Functions and Equipment in Detail
The relay features a changeover contact as the output contact, which switches the contact state when the relay operates. The contact configuration is therefore suitable for controlling auxiliary circuits, signal lamps, alarms, or other control devices. The contact rating is up to 4 A for AC 24 V to 380 V with a power factor of 1 to 0.7, and up to 3 A with a power factor of 0.4. For direct current, the rating is up to 1 A at 24 V to 220 V with resistive load and up to 0.5 A with inductive load. The electrical life is 5 million switching operations at a switching frequency of 3000 operations per hour and 30 % of switching capacity. The thermal current (Ith) is 6 A. The relay operates without auxiliary voltage, enabling simple installation and maintenance.
Technology Explained Simply
The AI 838 operates as an inductive measuring relay, detecting current in the measuring circuit via an integrated current transformer or directly through the input terminals i and k. The internal resistance of the relay varies depending on the measuring range; for the 0.5 to 1 A range, it is 4.45 Ohm. The overload capacity is limited to 1.0 times the scale end value for continuous operation up to 12 A, and to 2.0 times for short durations (1 second). The rated power consumption is less than 18 VA for alternating voltage. The repeatability accuracy is ≤ ±2 % for alternating current and ≤ 15 % for direct current. The contact configuration is designed for high switching durability, with life depending on load and switching frequency.
Compatibility and Accessories
The relay is suitable for use with current transformers to extend the measuring range. For currents above 16 A, a current transformer with a secondary rated current of 5 A (e.g., type KSW 73 from Ritz Instrument Transformers GmbH) can be used. The measuring range shift due to different lead lengths is shown in the datasheet. For direct current measurements with higher currents, a shunt can be connected in parallel with the relay. The information on measuring range extension refers to a lead with a resistance of approximately 0.5 mΩ (corresponding to 0.30 m length with 10 mm² cross-section made of E-Cu) and an ambient temperature of 20 °C.
Mounting and Installation
The relay is mounted in enclosures and designed for installation in standard control panels with a width of 45 mm. The connection terminals i and k serve as the current input, while contacts 11, 12, and 14 form the changeover contact. Mounting is done via screw fastening, with electrical connections to be made according to the specifications in the datasheet. The switching delay of approximately 100 ms must be considered when planning control sequences.
Operational Advantages
The AI 838 provides precise and reliable current monitoring without auxiliary voltage, simplifying installation and enhancing operational safety. The continuous adjustment of the pickup value allows flexible adaptation to different applications. The high electrical life and robust construction ensure long service life. Compliance with IEC/EN 60255-1 guarantees adherence to international standards for measuring instruments in electrical installations. The integrated hysteresis prevents unwanted switching operations due to minor fluctuations around the pickup value.