| Certificates |
| Certification | RoHS, REACH
IEC 60950,VDE |
| Design |
| PDU types | Metered |
| Type | Single-phase |
| Rack capacity | 0U |
| Mounting | Vertical |
| Product colour | Black |
| Features |
| Cable length | 3 m |
| Logistics data |
| Total carbon footprint (kg of CO2e) | 28921.23 |
| Management features |
| Monitoring | Current, Power, Voltage |
| Operational conditions |
| Operating temperature (T-T) | 5 - 45 °C |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Ports & interfaces |
| AC outlets quantity | 42 AC outlet(s) |
| Power plug | IEC309 |
| AC outlet types | C13 coupler, C19 coupler |
| Input connection type | IEC 309 32A 2P+E |
| Output connections | 36x IEC 320 C13
6x IEC 320 C19 |
| Power |
| AC input frequency | 50 - 60 Hz |
| Nominal output voltage | 230 V |
| Load capacity | 7680 VA |
| Maximum input current per phase | 32 A |
| Maximum total current draw per phase | 32 A |
| Maximum power | 7680 W |
| Weight & dimensions |
| Width | 56 mm |
| Depth | 44 mm |
| Height | 1791 mm |
| Weight | 6.93 kg |
The APC Rack power distribution unit AP8853 is a
measurement device for use in data centres and IT infrastructures. It is a
0U rack PDU with
single-phase power supply, mounted vertically and featuring a
black front panel. The device is designed for distributing and monitoring electrical power to IT equipment and enables precise control of power consumption measurement. The
load capacity is 7680 VA, equivalent to a maximum power of 7680 W. The nominal output voltage is 230 V, and the maximum input current per phase is 32 A. The input connection is via an
IEC 309 32A 2P+E plug, and the device includes a
3 m long power cable. The operating temperature ranges from 5 °C to 45 °C, and the relative humidity during operation is 5 % to 95 %.
Applications
The AP8853 is specifically designed for use in
rack systems where precise power distribution and monitoring are required. It is suitable for data centres, server rooms, and other IT environments where continuous power supply and avoidance of overloads are critical. The measurement functions enable detailed analysis of energy consumption, which is important for planning and optimising IT infrastructures. The devices can be integrated into existing rack systems without requiring additional space, as they are designed as
0U modules.
Functions and Equipment in Detail
The device features a total of
42 AC outlets, distributed as
36x IEC 320 C13 and
6x IEC 320 C19 sockets. These socket types are standard in IT systems and allow powering of various devices, from servers to network switches. The
C13 and C19 couplers are equipped with locking mechanisms to ensure a secure and stable connection. The
ultra-thin circuit breakers allow for easy and quick disconnection of individual circuits without interrupting the entire circuit. The
monitoring functions include measurement of
current, power, and voltage, enabling real-time tracking of actual energy consumption.
Technology Explained Simply
The
measurement function of the AP8853 continuously captures the electrical parameters of the circuit. The data is displayed locally on the device and can be retrieved via a secure web connection,
SNMP- or
Telnet interface. Users can set individual
alarm threshold values, triggering warnings in case of impending overloads. These warnings are displayed both locally on the device and on remote systems to enable quick response. The
energy consumption data supports data centre managers in decision-making regarding load distribution and dimensioning of IT environments, thereby reducing overall operating costs.
Compatibility and Accessories
The AP8853 is designed for integration into existing rack systems and can be combined with various APC platforms for central management, including
InfraStruxure Central, Operations, Capacity, and Energy Efficiency. These platforms enable central control and monitoring of multiple PDUs and IT systems. The devices are designed for use in
rack systems that support vertical mounting. The
IEC 309 connection at the input is standard in many rack systems and ensures a secure power supply.
Installation and Mounting
Mounting is done vertically in the rack, with the device occupying no rack units (HE). Installation requires no special tools, as mounting is done using integrated fastening elements. Connection to the power grid is via the 3 m long power cable with IEC 309 plug. Configuration of monitoring and alarm functions is done via the web or network interface, with access rights managed through user accounts. The devices are designed for indoor use, with operating conditions specifying an ambient temperature of 5 °C to 45 °C and humidity of 5 % to 95 %.
Operational Advantages
The
measurement function enables precise energy consumption analysis, which is crucial for optimising IT infrastructures.
Real-time monitoring and the ability to define
alarm threshold values help detect and avoid potential overloads early.
Central control via APC platforms enables efficient management of multiple PDUs and IT systems. The
locking sockets ensure a secure connection, and the
ultra-thin circuit breakers simplify maintenance and operation. The
certification according to RoHS, REACH, IEC 60950, and VDE ensures compliance with international safety and environmental standards.
Certification and Environment
The device complies with the requirements of
RoHS (Restriction of Hazardous Substances in electrical and electronic equipment) and
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals), confirming the environmental compatibility and safety of the product. Additionally, it is certified according to
IEC 60950 and
VDE, ensuring electrical safety and conformity with European standards. The total carbon dioxide footprint is 28921.23 kg CO2e, reflecting the environmental balance of the product.
Operating Conditions
The device is designed for operation within a temperature range of 5 °C to 45 °C. The relative humidity during operation may range from 5 % to 95 %. For storage, temperatures from -25 °C to 65 °C and humidity from 5 % to 95 % are permissible. Dimensions are 56 mm (width), 44 mm (depth), and 1791 mm (height), with a weight of 6.93 kg. The devices are designed for indoor use, requiring a controlled environment for operation.