APC AP8853, EAN: 0731304277019

APC AP8853 Rack PDU 36x C13 6x C19

Networks > Accessories > Modules / extensions

APC AP8853 Rack PDU 36x C13 6x C19

Lieske Part No. 2013594
Mfg Part No AP8853
EAN-Code 0731304277019
Manufacturer APC
Here only 1.700,50 EUR
2.023,59 EUR incl. VAT

Further information for APC AP8853 Rack PDU 36x C13 6x C19

Certificates
CertificationRoHS, REACH IEC 60950,VDE
Design
PDU typesMetered
TypeSingle-phase
Rack capacity0U
MountingVertical
Product colourBlack
Features
Cable length3 m
Logistics data
Total carbon footprint (kg of CO2e)28921.23
Management features
MonitoringCurrent, Power, Voltage
Operational conditions
Operating temperature (T-T)5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Ports & interfaces
AC outlets quantity42 AC outlet(s)
Power plugIEC309
AC outlet typesC13 coupler, C19 coupler
Input connection typeIEC 309 32A 2P+E
Output connections36x IEC 320 C13 6x IEC 320 C19
Power
AC input frequency50 - 60 Hz
Nominal output voltage230 V
Load capacity7680 VA
Maximum input current per phase32 A
Maximum total current draw per phase32 A
Maximum power7680 W
Weight & dimensions
Width56 mm
Depth44 mm
Height1791 mm
Weight6.93 kg
The APC Rack power distribution unit AP8853 is a measurement device for use in data centres and IT infrastructures. It is a 0U rack PDU with single-phase power supply, mounted vertically and featuring a black front panel. The device is designed for distributing and monitoring electrical power to IT equipment and enables precise control of power consumption measurement. The load capacity is 7680 VA, equivalent to a maximum power of 7680 W. The nominal output voltage is 230 V, and the maximum input current per phase is 32 A. The input connection is via an IEC 309 32A 2P+E plug, and the device includes a 3 m long power cable. The operating temperature ranges from 5 °C to 45 °C, and the relative humidity during operation is 5 % to 95 %.

Applications

The AP8853 is specifically designed for use in rack systems where precise power distribution and monitoring are required. It is suitable for data centres, server rooms, and other IT environments where continuous power supply and avoidance of overloads are critical. The measurement functions enable detailed analysis of energy consumption, which is important for planning and optimising IT infrastructures. The devices can be integrated into existing rack systems without requiring additional space, as they are designed as 0U modules.

Functions and Equipment in Detail

The device features a total of 42 AC outlets, distributed as 36x IEC 320 C13 and 6x IEC 320 C19 sockets. These socket types are standard in IT systems and allow powering of various devices, from servers to network switches. The C13 and C19 couplers are equipped with locking mechanisms to ensure a secure and stable connection. The ultra-thin circuit breakers allow for easy and quick disconnection of individual circuits without interrupting the entire circuit. The monitoring functions include measurement of current, power, and voltage, enabling real-time tracking of actual energy consumption.

Technology Explained Simply

The measurement function of the AP8853 continuously captures the electrical parameters of the circuit. The data is displayed locally on the device and can be retrieved via a secure web connection, SNMP- or Telnet interface. Users can set individual alarm threshold values, triggering warnings in case of impending overloads. These warnings are displayed both locally on the device and on remote systems to enable quick response. The energy consumption data supports data centre managers in decision-making regarding load distribution and dimensioning of IT environments, thereby reducing overall operating costs.

Compatibility and Accessories

The AP8853 is designed for integration into existing rack systems and can be combined with various APC platforms for central management, including InfraStruxure Central, Operations, Capacity, and Energy Efficiency. These platforms enable central control and monitoring of multiple PDUs and IT systems. The devices are designed for use in rack systems that support vertical mounting. The IEC 309 connection at the input is standard in many rack systems and ensures a secure power supply.

Installation and Mounting

Mounting is done vertically in the rack, with the device occupying no rack units (HE). Installation requires no special tools, as mounting is done using integrated fastening elements. Connection to the power grid is via the 3 m long power cable with IEC 309 plug. Configuration of monitoring and alarm functions is done via the web or network interface, with access rights managed through user accounts. The devices are designed for indoor use, with operating conditions specifying an ambient temperature of 5 °C to 45 °C and humidity of 5 % to 95 %.

Operational Advantages

The measurement function enables precise energy consumption analysis, which is crucial for optimising IT infrastructures. Real-time monitoring and the ability to define alarm threshold values help detect and avoid potential overloads early. Central control via APC platforms enables efficient management of multiple PDUs and IT systems. The locking sockets ensure a secure connection, and the ultra-thin circuit breakers simplify maintenance and operation. The certification according to RoHS, REACH, IEC 60950, and VDE ensures compliance with international safety and environmental standards.

Certification and Environment

The device complies with the requirements of RoHS (Restriction of Hazardous Substances in electrical and electronic equipment) and REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals), confirming the environmental compatibility and safety of the product. Additionally, it is certified according to IEC 60950 and VDE, ensuring electrical safety and conformity with European standards. The total carbon dioxide footprint is 28921.23 kg CO2e, reflecting the environmental balance of the product.

Operating Conditions

The device is designed for operation within a temperature range of 5 °C to 45 °C. The relative humidity during operation may range from 5 % to 95 %. For storage, temperatures from -25 °C to 65 °C and humidity from 5 % to 95 % are permissible. Dimensions are 56 mm (width), 44 mm (depth), and 1791 mm (height), with a weight of 6.93 kg. The devices are designed for indoor use, requiring a controlled environment for operation.