| Certificates |
| Compliance certificates | RoHS |
| Certification | cUL, UL, REACH |
| Design |
| PDU types | Basic |
| Type | Single-phase |
| Rack capacity | 0U/2U |
| Mounting | Horizontal/Vertical |
| Product colour | Black |
| Operational conditions |
| Operating temperature (T-T) | 0 - 50 °C |
| Storage temperature (T-T) | -15 - 65 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Packaging data |
| Package weight | 2.55 kg |
| Package width | 123 mm |
| Package depth | 107 mm |
| Package height | 612 mm |
| Ports & interfaces |
| AC outlets quantity | 14 AC outlet(s) |
| Power plug | C20 coupler |
| AC outlet types | C13 coupler |
| Input connection type | IEC-320 C20 |
| Power |
| Nominal input voltage | 230 V |
| AC input frequency | 50 - 60 Hz |
| Maximum current | 20 A |
| Nominal output voltage | 100-240 V |
| Load capacity | 3680 VA |
| Maximum input current per phase | 16 A |
| Maximum total current draw per phase | 16 A |
| Maximum power | 3680 W |
| Weight & dimensions |
| Width | 56 mm |
| Depth | 47 mm |
| Height | 523 mm |
| Weight | 1.88 kg |
The APC Basic Rack PDU AP6003A is a
power distribution unit for installation in server or network racks. It is designed for distributing electrical power to multiple devices within a rack and is intended for use in IT infrastructures, data centers, or server rooms. The device features a
single-phase power input and is configured as a
standard PDU, with a height specified as 0U/2U. Mounting can be done both
horizontally and
vertically, enabling flexible installation in various rack layouts. The
product color is black, allowing for discreet integration into typical server environments.
Applications
The PDU is designed for use in professional IT environments where reliable power supply to multiple devices from a central input is required. It is particularly suitable for racks containing servers, network equipment, storage solutions, or other IT components that connect via standard C13 outlets. The
operating temperature range of 0 to 50 °C and the
storage temperature range of -15 to 65 °C allow use in a wide variety of environments, including rooms with controlled climate. The
relative humidity during operation is 0 to 95 %, non-condensing, ensuring safe installation in standard server rooms. The maximum operating altitude is 3000 m above sea level, permitting use at higher elevations.
Functions and Features in Detail
The APC AP6003A features
14 AC outputs in the form of
C13 connectors, designed for compatibility with standard IT devices. The
nominal input voltage is 230 V, with the PDU supporting an input voltage range of 100 to 240 V AC. The
input frequency is between 50 and 60 Hz, enabling global usability. The
maximum current is 20 A, with a maximum total current draw per phase of 16 A. The
load capacity is specified as 3680 VA, equivalent to a maximum power of 3680 W. The output voltage is also within the 100 to 240 V range, ensuring stable operation even with fluctuating line voltages.
Technology Explained Simply
The PDU functions as a
power distributor, routing electrical power from a central source (e.g., a power supply or UPS) to multiple end devices. The use of C13 outlets ensures compatibility with most IT and network equipment. Single-phase technology is common for standard networks and is sufficient for most server and network environments. The
maximum current per phase of 16 A (cULus) or 20 A (PSE) ensures adequate capacity for multiple devices. The
dimensions are 523 mm (height) × 56 mm (width) × 47 mm (depth), representing a compact form factor for half-rack height. The
weight is 1.88 kg, enabling easy handling and installation.
Compatibility and Accessories
The PDU is equipped with an
IEC-320 C20 input, which connects to a separate power cord. The outputs are configured as
C13 connectors, universally compatible with IT devices. The PDU is designed for use in racks with a height of 0U/2U, allowing installation in standard 19-inch racks. The
certifications include cUL, UL, REACH, and RoHS, confirming compliance with international safety and environmental standards. The PDU is therefore suitable for use in many countries, particularly in regions recognizing UL and RoHS standards.
Installation and Mounting
Mounting is done via horizontal or vertical attachment within the rack. The 0U/2U height allows flexible placement, with the PDU either directly hung into the rack frame or mounted on the rear panel. Connection to the power supply is made via a separate power cord with a C20 plug, connected to the PDU. Installation requires no special tools, as mounting is done using standard screws. The PDU is designed for use in racks with a depth of at least 47 mm.
Operational Advantages
The APC AP6003A provides
reliable power distribution for multiple devices from a single input. The
14 C13 outputs enable simultaneous power supply to multiple IT components, reducing the number of required power cords. The
global voltage compatibility of 100 to 240 V AC and support for 50/60 Hz frequency allow use in various countries. The
certifications such as UL, cUL, and RoHS guarantee safe and environmentally compliant operation. The
compact design and the option for horizontal and vertical mounting increase flexibility during installation in existing rack systems. The PDU is thus a robust and universally applicable solution for power supply in IT infrastructures.