Further information for ABB Automation 2CSR254101R1407 residual current circuit breaker DS204 A-K40/0.03
General
Rated current
40
Rated fault current
30
Number of protected poles
4
Release characteristic
K
Breaking capacity
6
Number of earth leakage circuit breakers
1
Height
93
Width
105
Depth
69
Concurrently switching N-neutral
Wiring on terminal strip
The ABB residual current circuit breaker DS204 A-K40/0.03 is an FI/LS combination switch (RCBO) designed for use in electrical installations in residential, commercial, and industrial applications. It combines the functions of a circuit breaker (LS) and a residual current circuit breaker (FI) in one device, ensuring both personal and property protection. The protection functions include protection against indirect contact, additional protection with a rated residual current of 30 mA, and fire protection with a rated residual current of 300 mA. The device complies with product standard IEC/EN 61009-1 (VDE 0664-20) and is suitable for use in accordance with DIN VDE 0100-410 and DIN VDE 0100-530.
Applications
The DS204 A-K40/0.03 is designed for use in electrical installations requiring protection against overload, short circuit, and fault currents. It is suitable for 4-pole circuits and provides protection for sinusoidal alternating currents as well as for pulsating currents with a smooth direct fault current component up to 6 mA. Application areas range from residential buildings to commercial and industrial facilities, with certifications enabling worldwide use.
Functions and Equipment in Detail
The device has a rated current of 40 A and a rated residual current of 30 mA. The tripping characteristic is K, meaning the switch responds to overloads with a current increase above the rated current, with tripping beginning at approximately 1.3 times the rated current. The number of protected poles is 4, with the neutral conductor not switching. The combination of FI and LS functions enables an integrated protection function that detects and disconnects both electrical overloads and fault currents.
Technology Explained Simply
The switch is designed as an RCBO (Residual Current Breaker with Overcurrent protection), meaning it detects and disconnects both fault currents and overload and short-circuit currents. The breaking capacity is 6 kA, which is sufficient for use in residential and similar applications. The rated switching capacities are Icn = 6,000 A for the RCD function (residual current protective device) and Icu = 10 kA for the MCB function (circuit breaker), with the latter being relevant for industrial applications.
Compatibility and Accessories
Various accessories are available for this device, extending its functionality. These include the S2C-S/H6R auxiliary switch with 1 changeover contact for LS and FI, as well as the S2C-H6R auxiliary switch 1 changeover contact system per M compact. These auxiliary switches enable remote control or signal output of the switch, allowing integration into more complex control and monitoring systems.
Mounting and Installation
The switch is designed for modular installation and has dimensions of 93 mm (height), 105 mm (width), and 69 mm (depth). Installation requires compliance with applicable VDE standards and correct wiring of the poles. The number of combinations of residual current switch/circuit breaker is 1, meaning the device is installed as a single unit.
Operational Advantages
The DS204 A-K40/0.03 offers a compact solution for protecting electrical installations, as it integrates the functions of two devices in one. The combination of FI and LS protection reduces space requirements in the distribution box and simplifies installation. Protection against overload, short circuit, and fault currents increases the safety of the installation. Certifications for worldwide use increase flexibility in planning and installation.