Xaver Bechtold 40410401, EAN: 4046725003199

Xaver Bechtold 40410401 cable UL-CSA-H05V2-K0,75 AWG20 blue

Cables > Installation systems and industrial management > Wiring cable H05 / 07V-K

Xaver Bechtold 40410401 cable UL-CSA-H05V2-K0,75 AWG20 blue

Lieske Part No. 379258
Mfg Part No 40410401
EAN-Code 4046725003199
Manufacturer Xaver Bechtold
Here only 46,11 EUR
54,87 EUR incl. VAT

Further information for Xaver Bechtold 40410401 cable UL-CSA-H05V2-K0,75 AWG20 blue

General
Nominal voltageUL/CSA 600 V
Test voltage5 kV
Installation temperature range-5 °C
Temperature range after installation-40 °C
Operation temperature+105 °C
Bending radius for single bending5 x cable diameter
Bending radius for multiple bending10 x cable diameter
Conductortinned copper stranded wire
Conductor classVDE 0295, Class 5
InsulationPVC according to UL standard 1581, Class 43, Type VW-1
Sheath colourBlue
Resistant tooil, solvents, acids, alkalis
UL typeAMW 105° 600 V
CSA typeTEW 105° 600 V
Type markingYes
Self-extinguishingYes
Flame retardantYes
The wiring cable UL-CSA-H05V2-K0,75 AWG20 BL ST.1015 from Xaver Bechtold is a flexible, fine-stranded installation cable for use in electrical devices and enclosures. It is suitable for internal wiring of household appliances, radio and television equipment, as well as control panels. Additionally, it is used as a connection cable between machines in protective conduits and tubes, and as a connection cable for motors and transformers. The cable is fitted with a blue PVC sheath, coloured according to VDE 0293-308, and features a type marking to facilitate identification during operation.

Applications

The cable is designed for use in industrial and commercial installations as well as in household appliances. It is frequently used in enclosures, controls, and electronic devices where a flexible and pull-resistant connection is required. Its use in protective conduits and tubes enables protection against mechanical stress and ensures proper cable routing. The connection function for motors and transformers also makes it suitable for use in machine and plant engineering.

Functions and Equipment in Detail

The cable consists of a tinned copper stranded conductor, manufactured fine-stranded according to VDE 0295, Class 5, Specification 3. This construction ensures high flexibility and bending strength, especially under repeated bending. Insulation is provided by PVC, which meets UL Standard 1581, Class 43, Type VW-1. This standard guarantees high heat and moisture resistance, as well as self-extinguishing and flame-retardant properties. The cable is largely resistant to oil, solvents, acids, and alkalis, making it suitable for demanding environments.

Technology Explained Simply

The rated voltage is UL/CSA 600 V, indicating the maximum voltage the cable can safely transmit. Additionally, the rated voltage for H05V2-K is specified as 450/750 V, demonstrating its suitability for various standard environments. The test voltage varies depending on the AWG cross-section: for AWG 20 and 22, it is 5 kV, highlighting the electrical strength of the insulation. The maximum operating temperature is +105 °C, with the cable tolerating temperatures from -5 °C to +105 °C during installation. After installation, it can withstand temperatures from -40 °C to +105 °C. The bending radii are approximately 5 times the cable diameter for single bends and 10 times for repeated bends, ensuring flexibility and longevity under movement.

Compatibility and Accessories

The cable complies with UL (Underwriters Laboratories Inc., USA) and CSA (Canadian Standards Association, Canada) standards. The UL type designation AMW 105° 600 V and the CSA type designation TEW 105° 600 V refer to specific requirements for heat resistance and electrical performance. These standards are internationally recognised and enable use in various markets. The cable is designed for use in systems that meet these standards and can be combined with other components that are also UL- and CSA-certified.

Installation and Mounting

Installation is carried out by routing the cable in enclosures, device housings, or protective conduits. The flexible construction allows for easy routing and bending, with recommended bending radii to be observed to ensure service life. The cable can be processed using standard tools, such as cutting, soldering, or crimping connections. The use of protective conduits or tubes is recommended to avoid mechanical damage.

Advantages in Operation

The cable is characterised by high mechanical and thermal load capacity. The self-extinguishing and flame-retardant PVC insulation increases safety during operation. Resistance to chemical influences such as oil, solvents, acids, and alkalis makes it suitable for industrial applications. High flexibility and bending strength ensure a long service life, even under frequent movement. The clear type marking on the sheath facilitates identification and maintenance during operation.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/379258
qrcode für Xaver Bechtold 40410401 cable UL-CSA-H05V2-K0,75 AWG20 blue