| General |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +60 °C |
| Temperature range after installation | -20 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 4 x cable diameter (min.) |
| Conductor | Bare copper according to VDE 0295 |
| Wire insulation | Cross-linked polyethylene mixture |
| Conductor marking | according to VDE 0293-308 |
| Filler compound | Halogen-free and flame retardant |
| Outer sheath | Halogen-free and flame-retardant polymer blend |
| Sheath colour | Grey RAL 7001 |
| Burning behaviour | According to VDE 0472 T. 804, test type C (=IEC 332-1) |
| Corrosivity of fire gases | according to VDE 0472 T. 813 |
| Flue gas density | according to VDE 0472 T. 816, test type C (=IEC 1034-1) |
| Halogen-free | According to VDE 0472 Part 815 |
| Ozone resistance | According to VDE 0472 T. 805 |
| Flame retardancy | VDE 0482-266-2-4, IEC 60332-3-24 |
The NHXMH-J 1X4 cable from Xaver Bechtold is a halogen-free sheathed cable designed for use in buildings with high personnel and/or asset concentration. It is suitable for installation over, on, in, and under plaster, in dry, damp, and wet rooms, as well as in masonry and concrete. Direct embedding in vibrated, compacted, or rammed concrete is excluded. The cable is also suitable for outdoor use, provided environmental conditions remain within the specified temperature limits. The construction ensures minimal smoke development in case of fire, maintaining visibility in emergencies. Additionally, no corrosive or toxic gases are released, enhancing safety during fire events. The cable prevents fire spread due to its flame-retardant properties.
Applications
The NHXMH-J 1X4 is intended for use in residential and commercial buildings, industrial facilities, and public institutions where high fire protection requirements apply. Installation occurs indoors, in masonry, under plaster, or in concrete, but the cable must not be laid in freshly placed concrete. Outdoor use is possible, provided ambient temperature remains within the permitted range. The cable is particularly suitable for applications where smoke and toxic gas emissions must be minimized.
Functions and Equipment in Detail
The cable consists of a copper conductor in accordance with VDE 0295, which is either round single-strand or multi-strand. Insulation of the conductors is achieved using a cross-linked polyethylene mixture, providing high electrical insulation and mechanical stability. Conductor identification follows VDE 0293-308, enabling clear identification of conductors. The filler sheath is halogen-free and flame-retardant, as is the outer sheath, made of a polymer blend. The sheath color is gray, corresponding to RAL 7001, ensuring good visibility and identification.
Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage at which the cable can be safely operated. The test voltage of 2000 V serves quality assurance and ensures the insulation withstands increased electrical stress. The operating temperature is limited to a maximum of +70 °C, while during installation, the cable must tolerate temperatures from +5 °C to +60 °C. After installation, ambient temperature may range from -20 °C to +70 °C. The minimum bending radius is 4 times the cable diameter to prevent mechanical damage. Flame-retardant properties comply with standards VDE 0482-266-2-4 and IEC 60332-3-24, qualifying the cable for use in fire-hazardous areas.
Compatibility and Accessories
The cable is designed for use in electrical installations meeting requirements for halogen-free cables. It can be combined with other components of the same product family, provided electrical and mechanical requirements are compatible. Use in combination with other cables or wires is possible, provided installation specifications are observed. The cable is not intended for direct contact with aggressive chemicals or in highly corrosive environments.
Installation and Mounting
Installation must consider specified temperature and bending radius requirements. The cable must not be laid in freshly placed concrete, as this may cause mechanical damage. Installation in masonry or under plaster is permitted, provided the surrounding environment offers sufficient mechanical stability. Outdoor installation requires careful planning of environmental conditions, particularly temperature and humidity. The cable is suitable for indoor and outdoor use, provided technical specifications are followed.
Operational Advantages
The halogen-free design reduces fire hazard and toxic gas emissions in case of fire. Minimal smoke development improves visibility and facilitates evacuation. Flame-retardant properties prevent flame spread along the cable. High mechanical stability and ozone resistance ensure long service life. The cable is suitable for use in buildings with high personnel and asset concentration, making it ideal for public institutions, hospitals, schools, and industrial facilities. Outdoor use expands application scope and enables flexible installations in external systems.