General
Nominal voltage300/500 V
Test voltage4000 V
Temperature range in motion-5 °C
Temperature range, non-operating-40 °C
Bend radius for fixed installation4 x cable diameter
Bend radius flexible15 x cable diameter
Flame retardancyVDE 0472 T. 804 test type B (IEC 332-1)
ConductorCopper stranded wire, bare, fine-stranded in accordance with VDE 0295 Class 5
Wire insulationPVC
SheathPVC grey
Chemical resistanceresistant to acids, alkalis and certain hydrocarbon compounds
The control cable YSLY-JZ 4X10 from Xaver Bechtold is a flexible cable designed for use in industrial plants, particularly in machine tools, conveyor and assembly lines, and material handling systems. It is designed for fixed installation and flexible application, and can be used in free motion without tensile stress and without forced guidance. The cable is designed for medium mechanical stress and can be operated in dry, damp, and wet rooms. The designation YSLY-JZ indicates a control cable with PVC sheath, numbered conductors, and an integrated green-yellow protective conductor, making it suitable for use in electrical installations requiring a protective conductor.

Applications
The cable is used in industrial automation technology, where it transmits signals between control devices, sensors, and actuators. It is particularly suitable for installations where flexible cable movement is required, but there is no continuous tensile load or forced guidance. Possible applications include wiring of machines in manufacturing, logistics, or plant engineering. The cable is designed for indoor use, and can also be operated in damp or wet environments, provided there is no direct water exposure or permanent immersion.

Functions and Equipment in Detail
The cable consists of four conductors, each with a cross-section of 10 mm², made from bare, fine-stranded copper wires according to VDE 0295 Class 5. The conductors are insulated with PVC and marked with a numbered identification according to VDE 0293-308, where the marking JZ indicates black conductors with continuous digit printing and a green-yellow protective conductor. The conductors are stranded in layers, ensuring even distribution of mechanical stress and improved flexibility. The outer sheath is made of PVC and is gray in color. The designation, dimensions, and VDE registration number are printed on the sheath, enabling easy identification and documentation.

Technology Explained Simply
The rated voltage of the cable is 300/500 V, making it suitable for use in electrical installations with an operating voltage up to 500 V. The test voltage of 4000 V ensures electrical insulation and safety at high voltages. The temperature resistance is -5 °C to +70 °C for moving applications and -40 °C to +80 °C for fixed installation, enabling broad application in various environments. The bending radius is 4 times the cable diameter for fixed installation and 15 times for flexible application, facilitating mounting and installation. The flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), meaning the cable is only limitedly flammable and does not propagate a live flame in case of fire. The cable is largely resistant to chemical influences such as acids, alkalis, and certain hydrocarbon compounds, making it suitable for use in industrial environments with chemical exposure.

Compatibility and Accessories
The control cable YSLY-JZ 4X10 is compatible with standard connectors and cable glands designed for PVC insulation. It can be combined with other cables of the same type to create larger wiring systems. The numbered identification of the conductors simplifies assignment and wiring, especially in complex installations. The cable is designed for use in electrical installations requiring a protective conductor, with the integrated green-yellow protective conductor ensuring electrical safety.

Installation and Mounting
The cable is mounted by fixed installation or flexible arrangement, with the bending radius to be observed. For flexible application, a bending radius of at least 15 times the cable diameter must be maintained to avoid mechanical damage. The cable must not be installed under tensile stress, and forced guidance is not intended. Installation takes place in dry, damp, or wet rooms, with ambient temperature within the specified limits. The cable is intended for indoor use, and direct water exposure or permanent immersion should be avoided.

Operational Advantages
The control cable YSLY-JZ 4X10 offers high mechanical and chemical resistance, enabling long service life and low maintenance frequency. The numbered identification of the conductors simplifies installation and maintenance, especially in complex installations. The flame retardancy and electrical insulation ensure high safety during operation. The cable is suitable for a wide range of operating conditions, making it a versatile solution in industrial electrical engineering. The use of copper wires according to VDE 0295 Class 5 ensures high flexibility and durability, especially in moving applications.