General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 to +70 °C
Temperature range after installation-30 to +70 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 Part 814
Circuit integrityE 30 according to DIN 4102-12
Degree of protectionhalogen-free, flame-retardant, minimal smoke emission, no corrosive gases
Conductor markingaccording to VDE 0293-308
InsulationNetworked, halogen-free, ceramizing 2-layer insulation HXI2
Sheath colourOrange
ConductorCopper conductor, bare, solid or stranded
Common core sheathingYes
This product is a halogen-free power cable from manufacturer VDE-Kabel, type NHXH 3X2.5 E30, designed for use in installations with high safety requirements. It is intended primarily for supplying fire alarm systems, alarm and instruction systems, safety lighting, and emergency lighting in accordance with VDE 108. The cable is intended for indoor use, with installation in air, concrete, or in conduit (provided sufficient water drainage is ensured) being permitted. Direct installation in soil or water is not allowed. Installation must consider mechanical protection requirements, as the cable must be protected from external influences. It is suitable for connecting devices of protection class II.

Applications
This cable is used in areas where special protection against fire and fire damage is required to safeguard people and property. It is intended for installations that must continue to function even in the event of fire, such as fire alarm systems, safety lighting, and emergency power supplies. Testing for functional integrity according to DIN 4102 Part 12 (E30) has been successfully completed for all standard cable support systems (cable trays, ladders, ceiling installations). This makes the cable suitable for critical safety installations that must continue to operate at high temperatures during a fire.

Functions and Equipment in Detail
The cable features a cross-linked, halogen-free, ceramizing two-layer insulation (HXI2), providing high heat resistance and fire retardancy. Conductor identification follows VDE 0293-308. The common conductor sheathing protects individual conductors and ensures structural stability. The outer sheath is orange and made from a halogen-free polymer blend, contributing to fire retardancy and reduced smoke development. The cable is halogen-free, fire-retardant, exhibits minimal smoke development, and releases no corrosive gases in the event of fire.

Technical Explanation
The rated voltage is 300/500 V, sufficient for indoor power installations. The test voltage of 2000 V ensures high electrical strength. The temperature range during installation is between +5 °C and +70 °C, and after installation between -30 °C and +70 °C. The bending radius is 15 times the cable diameter for single-core and 12 times for multi-core conductors. Tests include flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C, insulation integrity FE 180 according to VDE 0472 T. 814, and functional integrity E 30 according to DIN 4102-12. During design, note that conductor resistance at 800 °C (final temperature during E30 test) is approximately four times higher than at 20 °C.

Compatibility and Accessories
The cable is intended for use in standard cable support systems such as cable trays, ladders, and ceiling installations. It is suitable for connecting devices of protection class II. Installation in conduit is permitted, provided no water accumulation can occur. It is not intended for direct installation in soil or water.

Installation and Mounting
Installation is carried out indoors, with cables requiring protection against mechanical damage and external influences. Installation in air, concrete, or conduit is permitted, with sufficient water drainage required for conduit installations. Bending radii depend on conductor structure (single- or multi-strand) and must be observed to maintain cable mechanical integrity.

Operational Advantages
The cable provides high safety in fire situations through the functional integrity test E30, ensuring that conductors continue to carry current even at high temperatures. The halogen-free composition minimizes the formation of toxic gases and smoke, facilitating evacuation. The ceramizing insulation increases heat resistance and prevents flame spread. Use in safety installations ensures reliability even under critical conditions.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/378364
qrcode für VDE-Kabel G326096 NHXH 3x2,5 E30 Cable orange halogen-free