VDE-Kabel G128096

VDE-Kabel G128096 NHXH-E30 5 X 25,0 cable orange halogen-free

Cables > Halogen-free cables and wires > Buy Halogen-free cables NHXH / NHXCH E 30/90

VDE-Kabel G128096 NHXH-E30 5 X 25,0 cable orange halogen-free

Lieske Part No. 983327
Mfg Part No G128096
EAN-Code
Manufacturer VDE-Kabel
Here only 24,88 EUR
29,61 EUR incl. VAT

Further information for VDE-Kabel G128096 NHXH-E30 5 X 25,0 cable orange halogen-free

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C
Temperature range after installation-30 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 T. 814
Circuit integrityE30 according to DIN 4102-12
Conductor markingVDE 0293-308
Sheath colourOrange
Conductor materialbare copper
Insulation typeNetworked, halogen-free, ceramizing 2-layer insulation HXI2
Featureshalogen-free, flame-retardant, minimal smoke emission, no corrosive gases
The VDE-Kabel NHXH-E30 5 X 25.0 is a halogen-free power cable specifically developed for applications with high fire protection requirements. It ensures safe energy supply in buildings where the protection of people and property in case of fire is of utmost importance. The cable is intended for indoor use and can be installed in air, concrete, or in conduit, provided that no water accumulation occurs in conduit installations. Direct installation in earth or water is not permitted. It is suitable for connecting devices of protection class II and meets the requirements for functional integrity according to DIN 4102 Part 12 (E30), qualifying it for use in fire alarm systems, alarm systems, emergency lighting, and standby lighting in accordance with VDE 108. The design of cable installations with functional integrity requires consideration that the conductor resistance at 800 °C (final temperature in E30 test) is approximately four times higher than at 20 °C.

Applications
This cable is used in areas where a high fire protection standard is required, such as hospitals, administrative buildings, schools, or public facilities. It is particularly suitable for systems that must continue to function during a fire to enable evacuation or ensure user safety. Installation is carried out indoors, with mechanical protection ensured by appropriate support systems such as cable trays, cable ladders, or ceiling installations. Conduit installation is permitted, provided the conduits are not filled with water.

Functions and Equipment in Detail
The cable features a cross-linked, halogen-free, ceramizing two-layer insulation (HXI2), providing high heat resistance and fire retardancy. Conductor identification follows VDE 0293-308, enabling clear identification of conductors. The common conductor sheathing and orange outer jacket made of halogen-free polymer mixture ensure clear visual distinction and additional protection. Conductors are made of bare copper, either single or multi-strand, ensuring good electrical conductivity.

Technology Explained Simply
The ceramization of the insulation means that at high temperatures, the insulation transforms into a ceramic layer, preventing electrical contact between conductors and thus maintaining cable functionality during a fire. The E30 functional integrity test according to DIN 4102-12 ensures the cable retains its electrical function for 30 minutes at a fire temperature of 800 °C. Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C, as well as insulation integrity FE 180 according to VDE 0472 T. 814, guarantee safe behavior in case of fire. The halogen-free composition prevents the release of toxic and corrosive gases and smoke formation, facilitating evacuation.

Compatibility and Accessories
The cable is designed for use in standard support systems such as cable trays, cable ladders, and ceiling installations. It is suitable for systems intended for emergency lighting, fire alarm systems, and alarm systems according to VDE 108. Installation requires adherence to specified bending radii: 15 times the cable diameter for single-core and 12 times for multi-core conductors. The rated voltage is 300/500 V, the test voltage is 2000 V. Temperature ranges are +5 °C to +70 °C during installation and -30 °C to +70 °C after installation.

Installation and Mounting
During installation, the cable must be protected against external mechanical influences. Installation is carried out indoors, with conduit installation only permitted if no water accumulation occurs. Bending radii must be observed to avoid damage to conductors or insulation. Installation in earth or water is not allowed. Conductor identification according to VDE 0293-308 facilitates correct assignment of conductors during installation.

Operational Advantages
The cable provides high safety in case of fire through E30 functional integrity, flame retardancy, and minimal smoke emission. The halogen-free composition protects people from toxic gases and prevents corrosion effects on electrical equipment. The ceramizing insulation ensures stable electrical insulation even at high temperatures. Use in safety systems guarantees that critical functions such as lighting or alarm systems continue to operate in emergencies.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/983327