Further information for Diverse I-YY 6X2X0,6 - YY BD 6x2x0 6 telecommunications installation cable
Telecommunications installation cable J-YY ... Bd
according to VDE 0815
Application:
Preferably in the stations and private branch for
Telecommunications installations in dry and damp rooms
as well as for
fixed installation on outer walls for protection against solar radiation.
Building:
Conductor: copper conductor, solid
blank
0.6 mm diameter
Insulation: PVC
Marking:
according to VDE 0815
Stranding: 4 cores for Star
four
Star quad to the bundle
Stranded to cable core
Film
Sheath: Grey PVC
Specifications:
Rated voltage: 300 V
Test voltage: 800 V
Loop resistance: 130 / km
Rated current: 2.5 A
Operating capacity: 100 nF / km
Insulation resistance: 100 km Mx
Capacitive
Couplings: K1 (800 Hz, 100 m) 300pF
Line Attenuation: 1.7 dB / km (800 Hz)
Temperature range: - 5 ° C - + 50 ° C
(During installation)
- 30 ° C - + 70 ° C
(After installation)
Operating temperature: + 70 ° C (max.)
Bending radius: 7,5 x cable diameter
2.5 x cable diameter
for single bending without
Train
Flame resistance according to VDE 0472 T. 804
Category B (= IEC 332-1)
Diameter in mm: 6 x 0.6 x 2
Outer diameter approx: 7.2
Copper content (kg / m%): 3.4 Type: I-YY 6x2x0, 6
Quantity: 1 MTR