VDE-Kabel 1007780, EAN: 8717511223898

VDE-Kabel 1007780 A-2Y(L)2Y 2x2x0,6 Telephone Cable

Cables > Underground cables > Telecommunications underground cable

VDE-Kabel 1007780 A-2Y(L)2Y 2x2x0,6 Telephone Cable

Lieske Part No. 633032
Mfg Part No 1007780
EAN-Code 8717511223898
Manufacturer VDE-Kabel
Here only 1,05 EUR
1,25 EUR incl. VAT

Further information for VDE-Kabel 1007780 A-2Y(L)2Y 2x2x0,6 Telephone Cable

General
Conductor diameter0,6 mm
Wire insulationPE
Nominal voltage225 V
Test voltage2000 V
Loop resistance130 Ohm/km
Current carrying capacity2,5 A
Operating capacity52 nF/km
Insulation resistance5 GOhm x km
Capacitive couplings K3300 pF/400 pF
Line attenuation1,04 dB/km
Installation temperature range-20 °C to +50 °C
Temperature range after installation-30 °C to +70 °C
Bending radius7.5 x cable diameter
Sheath markingTelephone handset, white marking
Conductor markingblack rings
StrandingStar quad, basic bundle, main bundle
SheathShielding layer made of aluminium tape with plastic coating, welded to PE sheath
The VDE-Kabel A-2Y(L)2Y 2X2X0,6 is a telecommunication underground cable designed for outdoor installation, intended for the transmission of low-frequency signals in telecommunication systems. It is typically used as a local loop or local connection cable, as a railway station telecommunication cable, or in industrial facilities. The cable construction complies with the standard DIN VDE 0816 Part 1 and is not approved for high-voltage installation purposes. Use in fire- or explosion-hazardous facilities is not permitted without adequate protective measures. The cables are generally approved for all operational sites, with restrictions for mine workers according to DIN VDE 0118 Part 1 to Part 3.

Applications
This cable is designed for underground installation and is primarily used in the low-frequency range, especially in the trunk network and preferably operated without spooling. It is suitable for connecting telecommunication systems, particularly in fixed infrastructures such as railway stations, industrial facilities, or for supplying local networks. Installation is carried out underground, with the cables exhibiting high mechanical stability and resistance to external influences.

Functions and Equipment in Detail
The cable consists of single-strand, bare copper conductors with a diameter of 0.6 mm. The conductors are insulated with polyethylene (PE), designated as 2Y. Conductor identification is achieved through black rings applied to the insulation. The stranding is performed in a star quad system: four conductors form a star quad, five star quads form a basic bundle, and five or ten basic bundles form a main bundle. These bundles are stranded to form the cable core. The core is wrapped with a layer sheath made of a 0.2 mm thick aluminium tape, coated on both sides with plastic, and welded to the outer PE sheath (black). The sheath marking is continuous, featuring the inscription “Fernsprech-Handapparat” and a white meter marking.

Technology Explained Simply
The rated voltage is 225 V, with a test voltage of 2000 V, highlighting the cable’s electrical strength. The loop resistance is 130 Ohm/km, typical for a conductor size of 0.6 mm. The current-carrying capacity is 2.5 A, indicating the maximum current draw during operation. The operating capacitance is 52 nF/km, and the insulation resistance is 5 GOhm x km, indicating high insulation quality. The capacitive couplings (K3) are 300 pF/400 pF at 800 Hz and a length of 300 m. The line attenuation is approximately 1.04 dB/km at 800 Hz, describing signal losses over the cable length. The temperature ranges are specified as -20 °C to +50 °C during installation and -30 °C to +70 °C after installation. The bending radius is 7.5 times the cable diameter, defining the flexibility during installation.

Compatibility and Accessories
The cable is designed for use in telecommunication systems and is typically used in conjunction with other telecommunication cables and connection or termination components. It is not intended for high-voltage applications. Installation is generally carried out underground, with cables laid in shafts, ducts, or directly in the ground. Compatibility with other cables of the same construction according to DIN VDE 0816 Part 1 is ensured.

Installation and Mounting
Installation requires adherence to the specified temperature ranges: -20 °C to +50 °C during laying and -30 °C to +70 °C after laying. The bending radius of 7.5 times the cable diameter must be maintained to avoid mechanical damage. Installation is carried out underground, with cables typically laid in shafts, ducts, or directly in the ground. The cables are designed for outdoor use and exhibit high mechanical stability.

Operational Advantages
The cable offers high electrical insulation quality, low line attenuation, and high mechanical stability. The PE insulation and PE sheath provide good resistance to external influences. The continuous meter marking and conductor identification facilitate installation and maintenance. Use in telecommunication systems enables reliable signal transmission in the low-frequency range.
This is an offer of: