Further information for TURCK inductive sensor KEMA 02 ATEX 1090X 1080020 - BI15-Q20-Y1X
Inductive sensor, rated switching distance 15 mm, flush, cable length 2 m, cuboid, height 20 mm, active surface at the top, plastic, PBT-GF30-V0, DC 2-wire, nom. 8.2 VDC, output according to DIN EN 60947-5-6 (NAMUR), cable connection, ATEX category II 2 G, Ex Zone 1, ATEX category II 1 D, Ex Zone 20, SIL2 (Low Demand Mode) according to IEC 61508, PL c according to ISO 13849-1 for HFT0, SIL3 (All Demand Mode) according to IEC 61508, PL e according to ISO 13849-1 for redundant configuration HFT1