Further information for TURCK Capacitive point level sensor 100004249 - NCLS-30-UN6X-H1141
Capacitive point level sensor, operating voltage 12.32 VDC, immersion sensor, media-contacting detection of limit levels in tanks and pipelines, detection of different substances (liquid, viscous, granular, powdery), hygienic PEEK tip, CIP / SIP capable, EHEDG certified (with process adapter NCLS-WA1), clearly visible ring LED, 12.32 VDC, power consumption: typ. 1 W, max. 3 W, two digital outputs, separately adjustable as normally open / normally closed, PNP, NPN or push-pull, switchable, IO-Link for parameterization / process values, process connection G1/2' external thread, hygienic (in conjunction with TURCK adapters), 4-pin plug device, M12x1