Further information for Softing NX_XG2_Plus_Trade_In network tester trade-in
General
Maximum data transfer rate
10 Gbit/s
Supported technologies
Copper, Fibre optic, WLAN
Copper measurement methods
Wiring diagram, BERT, SNR, Delay Skew
Fibre optic test
BERT according to IEEE 802.3
Plug end surface rating
Optional with fibre optic microscope
Supported protocols
CDP, LLDP, IPv4, IPv6
PoE support
up to 90 W
Documentation
PDF report generation
Battery type
6-cell high power battery
Accessories included in kit
2 x XG handheld device, 1 x end device, patch cable, power supplies, USB adapter, couplings, hard-shell case, 4 x upgrade license, manual
SFP module compatibility
Softing part no. 400982, 400984, 400985, 400986
Down payment
Against certifier with SNR, delay skew or BERT function
Cable length determination
The NetXpert XG2 Plus from Softing IT Networks is a professional network qualifier for testing copper and fiber optic cabling up to a transmission rate of 10 Gbit/s. The device is used for installation, commissioning, and troubleshooting in networks and combines active and passive test methods. It is designed for use in IT infrastructure, by network installers, and in industrial environments where high reliability and precise diagnosis are required.
Applications
The NetXpert XG2 Plus is used for qualifying network cables in copper and fiber optic technology. It is suitable for testing cabling in office buildings, data centers, industrial facilities, and for maintaining existing networks. The functions include checking for IEEE compliance, fault detection, cable length determination, and signal quality analysis. The integrated support for WLAN tests extends the application range to wireless networks.
Functions and Equipment in Detail
The device performs tests on copper cabling, combining four measurement methods: wiring map, Bit Error Rate Test (BERT), Signal-to-Noise Ratio (SNR), and length and delay skew differences. These methods ensure high reliability of the results. The display of the wiring map, cable lengths, and distance to breaks or short circuits enables precise fault localization. For fiber optic cabling, error-free transmission up to 10 Gbit/s is verified via a BERT test according to IEEE 802.3 standard. The LiveLight™ function shows fiber attenuation in real time and enables cable length determination. An automated evaluation of connector end faces is possible with an optional fiber optic microscope according to IEC 61300-3-35 standard.
Technology Explained Simply
The NetXpert XG2 Plus supports active network tests on copper, fiber optic, and WLAN. This includes connection status, DHCP test, Network-Discovery, PoE support up to 90 W, ping list, traceroute, VLAN detection, and detection of CDP and LLDP protocols. Support for IPv4 and IPv6 enables testing of modern networks. PDF report generation directly on the device simplifies documentation and handover to customers or clients. The devices are equipped with a 6-cell high-power battery, enabling mobile use.
Compatibility and Accessories
Specific SFP modules are required for fiber optic functions: Softing part numbers 400982, 400984, 400985, 400986. These modules support multimode and singlemode connections with different ranges and wavelengths. Suitable accessories include SFP modules for 1G and 10G Fiber Channel, as well as an Installer Kit containing patch cables, power supplies, USB adapters, and a hard-shell case. Combining with a fiber optic microscope enables evaluation of connector end faces.
Installation and Mounting
Installation is performed using the included patch cables and end devices. The devices are compact and designed for mobile use. Operation is via the integrated display, with results shown and documented directly on the device. The devices are designed for use in cabling networks executed according to IEEE and IEC standards.
Operational Advantages
The NetXpert XG2 Plus offers comprehensive network diagnostic functions, enabling fast fault detection and localization. The combination of passive and active tests increases the reliability of results. Integrated documentation in the form of PDF reports reduces administrative effort. Support for PoE up to 90 W and WLAN tests extends the application range. Mobile use enabled by the high-power battery and robust packaging in a hard-shell case make the device suitable for on-site use.
The offer includes a trade-in of an existing qualifier with SNR, Delay Skew, or BERT function against a new NetXpert XG2 Plus at a reduced price. The old cable tester must be returned to Softing within 30 days of purchase; otherwise, the list price will be charged. The price list already shows the reduced price.