Softing IT Networks 230524, EAN: 0046382255836

Softing IT Networks 230524

Softing IT Networks 230524

Lieske Part No. 225879
Mfg Part No 230524
EAN-Code 0046382255836
Manufacturer Softing IT Networks
Here only 573,44 EUR
682,39 EUR incl. VAT

Further information for Softing IT Networks 230524

The Softing IT Networks test cable kit is a specially configured accessory set for referencing and measuring in multimode fiber optic networks. It is designed for fiber optic links with LC/PC connectors and serves for precise analysis of transmission links, particularly in connection with the WireXpert MP system. The kit includes several test cables, couplers, and a cleaner, and is delivered in a Softbag for safe and organized transport of the components.

Applications

The kit is designed for the installation, maintenance, and diagnosis of multimode fiber optic networks, particularly in environments where 3-jumper referencing is required. This method is commonly used in network technology to measure the performance of fiber optic links under realistic conditions, taking into account the losses of connectors and couplers. The use of LC/PC connectors makes the kit especially suitable for modern, compact network infrastructures in offices, data centers, or industrial facilities.

Functions and Equipment in Detail

The set contains a total of six test cables: two for the transmit frequency (TX), two for the receive frequency (RX), and two additional multimode test cables without specific assignment. All cables are equipped with LC/PC connectors, ensuring a secure and clean optical connection. Additionally, two LC/PC duplex couplers are included, serving to connect two cables or extend the link. An LC OneClick fiber optic end-face cleaner ensures proper maintenance of the connectors, which is crucial for reliable signal transmission. The components are assembled in a Softbag, facilitating transport and storage.

Technology Explained Simply

The term multimode refers to the type of fiber optic cable in which multiple light modes are transmitted simultaneously. This allows for higher bandwidth and is suitable for short to medium distances. LC/PC connectors are small, precise connectors designed for low reflection (PC = Physical Contact) and high mechanical stability. The 3-jumper referencing is a standard procedure in fiber optic diagnostics, using three cables to measure actual losses in a link, accounting for losses from connectors and couplers.

Compatibility and Accessories

The kit is specifically developed for use with the WireXpert MP system, a measuring device for analyzing network cables. Compatibility with this device ensures accurate and standard-compliant measurements. The included components are tailored to the requirements of fiber optic networks with LC/PC connectors and can be directly integrated into existing infrastructures. The duplex couplers allow connection of two cables, increasing flexibility during link testing.

Installation and Mounting

Installation involves connecting the test cables to the link under test, with TX and RX cables positioned according to signal direction. The couplers serve to extend or connect cables. The cleaner is used before and after connector use to avoid contamination that could lead to signal loss. The Softbag facilitates transportation and storage of the components.

Operational Advantages

The pre-configured setup of the kit reduces preparation time for measurements and minimizes errors due to incorrect cable selection. The use of LC/PC connectors ensures high signal quality and low reflections. Including a cleaner in the set ensures clean end-faces, increasing the reliability of measurement results. The Softbag protects sensitive components and promotes structured working practices.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/225879
qrcode für Softing IT Networks 230524