| General |
| Number of devices | 2 |
| Mainframe type | WireXpert MP |
| Control system | Dual Control System PLUS (DCS+TM) |
| Copper measurement module | C8 |
| Maximum frequency copper | 3000 MHz |
| Certifiable copper cable classes | D, E, EA, F, FA, I, II and higher |
| Fibre optic measurement module | FM |
| Light source wavelengths | 850 nm, 1300 nm |
| Broadband power meter range | 700 nm - 1700 nm |
| Red light sources | 1.25 mm, 2.5 mm |
| Adapter for light sources and power meters | LC, SC |
| Battery type | Li-ion |
| Number of batteries | 2 |
| Power supplies | 2 |
| Carry bag | 1 |
| Calibration certificate | 1 |
| Evaluation software | eXport (Download) |
| CAT8.1 channel adapter | 2 |
| CAT8.1 Permanent-Link adapter | 2 |
| Longlife Permanent Link test cable | 1 |
| DCRU calibration artifact | 1 |
| Headsets | 2 |
| Quick start guide | 1 |
The WireXpert MP C8 + FM LAN Certifier Package from Softing IT Networks is a professional measurement system for certifying copper and multimode fiber network cables. It includes two WireXpert MP Mainframes with Dual Control System PLUS (DCS+TM), designed for precise and simultaneous measurement of two cables. The devices are designed for certifying copper cables of classes D, E, EA, F, FA, I, II and higher up to a frequency of 3000 MHz. Additionally, two fiber optic measurement modules FM are integrated, equipped with multimode light sources at 850 nm and 1300 nm, as well as a broadband power meter in the range of 700 nm to 1700 nm. The modules feature 1.25 mm and 2.5 mm red light sources, as well as LC and SC adapters for the light sources and power meter, enabling flexible adaptation to various cable types.
Applications
This certifier package is designed for use in the installation and maintenance of structured cabling systems in enterprises, buildings, and infrastructure projects. It serves for validating cables according to international standards such as ISO/IEC 11801, TIA/EIA-568, and EN 50173. Measurements are performed on both Channel and Permanent-Link levels, with the devices providing the necessary adapters for CAT8.1 connections. The integrated evaluation software eXport enables documentation and analysis of measurement results, ensuring compliance with quality standards can be proven.
Functions and Equipment in Detail
The package includes two WireXpert MP Mainframes, featuring a Dual Control System PLUS (DCS+TM) to enable simultaneous measurement of two cables. The copper measurement modules C8 support frequencies up to 3000 MHz and are suitable for certifying cables of classes D to II and higher. The fiber optic measurement modules FM are equipped with light sources for 850 nm and 1300 nm, as well as a broadband power meter operating in the spectrum from 700 nm to 1700 nm. The red light sources with 1.25 mm and 2.5 mm diameters are used for visual fault localization. The delivery includes two Li-ion batteries, two power supplies, a carrying bag, a calibration certificate, the evaluation software eXport (as download), two CAT8.1 Channel adapters, two CAT8.1 Permanent-Link adapters, Longlife Permanent Link test cables, a DCRU calibration artifact, and two speaker sets. The quick start guide supports setup and initial measurements.
Technology Explained Simply
The WireXpert MP Mainframes utilize the Dual Control System PLUS (DCS+TM), enabling parallel measurement of two cables, thereby reducing working time compared to single devices. The copper measurement modules C8 measure electrical properties of cables up to 3000 MHz, which is required for modern high-speed networks. The fiber optic measurement modules FM use light sources at 850 nm and 1300 nm, typical for multimode fibers, and a broadband power meter that measures optical power across a broad spectrum. The red light sources assist in visually locating cables and faults. The integrated evaluation software eXport enables report generation and storage of measurement results.
Compatibility and Accessories
The system is compatible with various optional accessories. These include singlemode test cables in different configurations (e.g. SC-LC/APC, LC-LC/APC), hard-shell cases, headsets, adapter modules for SC/PC, LC/PC, and LC interfaces, as well as reference couplers. These accessories extend the system's functionality for specific applications, such as measuring singlemode fibers or use in mobile field operations. Combining the system with a Cable Tracker Probe (e.g. CP15) enables cable location in existing installations.
Mounting and Installation
The devices are designed for field use and require no special mounting. Measurement is performed by directly connecting the Mainframes to the cables under test using the provided adapters. The speaker sets enable communication between the two measurement partners during testing. The carrying bag provides protection and transport capability for the devices. The quick start guide supports initial setup.
Operational Advantages
The simultaneous measurement of two cables via the Dual Control System PLUS (DCS+TM) increases efficiency during network installation and maintenance. The integrated evaluation software eXport enables documented and traceable testing according to standards. The versatility of the measurement modules for copper and multimode fiber cables makes the system universally applicable. The provision of calibration certificates ensures measurement accuracy and recognition of results in professional environments.