Schneider Electric XPSUS12AP, EAN: 3606489601812

Schneider Electric XPSUS12AP Safety Relay 24V

Schneider Electric XPSUS12AP Safety Relay 24V

Lieske Part No. 1593175
Mfg Part No XPSUS12AP
EAN-Code 3606489601812
Manufacturer Schneider Electric
Here only 245,10 EUR
291,67 EUR incl. VAT

Further information for Schneider Electric XPSUS12AP Safety Relay 24V

Complementary
Synchronisation time between inputs0.5 s; 2 s; 4 s
Type of startAutomatic/manual/monitored
Power consumption in W2 W 24 V DC
Power consumption in VA5.0 VA 24 V AC 50/60 Hz
Input protection typeInternal, electronic
safety outputs2 NO
safety inputs2 safety input 24 V DC 5 mA
maximum wire resistance500 Ohm
Input compatibilityNormally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; Two-hand control conforming to EN 574/ISO 13851-III A; Two-hand control conforming to EN 574/ISO 13851-III C; 3-wire proximity sensors PNP
[Ie] rated operational current5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
control outputs3 on/off configurable pulsed output
Input/output typeSemiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Ith] conventional free air thermal current8 A
Associated fuse rating10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current10 mA for relay output
Minimum output voltage12 V for relay output
Maximum response time on input open20 ms
[Ui] rated insulation voltage250 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage4 kV overvoltage category II conforming to IEC 60947-1
Local signallingLED (green) for power ON; LED (red) for error; LED (yellow) for safety output status; LED (yellow) for start input; LED (yellow) for safety input S12; LED (yellow) for safety input S13; LED (yellow) for safety input S22; LED (yellow) for safety input S23
Mounting support35 mm symmetrical DIN rail
Depth120 mm
Height100 mm
Width22.5 mm
Net weight0.200 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsIEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard
Product certificationsTÜV; cULus
IP degree of protectionIP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529
Ambient air temperature for storage-25…85 °C
Relative humidity5…95 % non-condensing
Logistical informations
Country of originID
Main
Range of productHarmony Safety Automation
Product or component typeSafety module
Safety module nameXPSUS
Safety module applicationFor electrical monitoring of two-hand control stations; Monitoring antivalent contacts; For emergency stop, guard and light curtain monitoring; For enabling switch monitoring
Function of moduleEmergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Enabling switch monitoring; Proximity sensor monitoring; Monitoring two-hand control station
Safety levelCan reach PL e/category 4 conforming to ISO 13849-1; Can reach SILCL 3 conforming to IEC 62061; Can reach SIL 3 conforming to IEC 61508
Safety reliability dataMTTFd > 30 years conforming to ISO 13849-1; Dcavg >= 99 % conforming to ISO 13849-1; PFHd = 1.13E-09 conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 1.13E-09 conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 1.13E-09 conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1
Electrical circuit typeNC pair; PNP pair; Antivalent pair; OSSD pair
Connections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage24 V AC - 15...10 %; 24 V DC - 20...20 %
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width13.500 cm
Package 1 Length16.000 cm
Package 1 Weight279.000 g
Unit Type of Package 2S03
Number of Units in Package 216
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.133 kg
Unit Type of Package 3P06
Number of Units in Package 3128
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight47.500 kg
The Harmony XPS Universal safety relays are ideal for use in a variety of safety applications thanks to their selectable safety function and start option using rotary switches on the front. This reduces the variety of devices required and the diagnostic function allows states to be easily transferred to a PLC, so that in the event of a fault, downtime is reduced by clear error information. The required function can be easily set from 10 selectable safety functions. Mechanical contacts from emergency stop/stop buttons, position, magnetic, enabling switches, two-hand operation type IIIC, PNP sensors, light curtains or RFID safety switches with OSSD outputs can be connected to the inputs. A safety function can be operated via the 4 inputs in 2x two-channel (redundant) versions. Automatic, manual or monitored start as well as an optional start-up test are available for the start function. This safety switching device has 2 safe relay normally open contacts and 1 diagnostic message as outputs. With the help of qualified diagnostics, states and errors are detected and transmitted to a standard input of a PLC using a telegram via direct wiring. A ready-made function block for common control systems evaluates these messages so that the operator is comprehensively informed on the machine display. The supply voltage is 24 VAC/DC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 4 or SIL3 can be realized. If the number of outputs is to be increased, the XPSUEP extension can simply be connected to the side via an integrated connector and cross-wiring can be dispensed with, saving time. Installation is carried out by snapping it onto a top hat rail or screwing it onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium environmental label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1593175
qrcode für Schneider Electric XPSUS12AP Safety Relay 24V