| Complementary |
| rest time in memory mode | 50 ms contact S2 in memory mode on time delay; 1 s supply Un in memory mode on time delay |
| Maximum switching voltage | 250 V AC/DC |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Supply voltage limits | 20.4…264 V AC/DC |
| Maximum power consumption in W | 3 W DC |
| Width | 35 mm |
| Output contacts | 1 C/O |
| Contacts material | Cadmium free |
| nominal output current | 5 A |
| delay at power up | 0.05 s |
| Hysteresis | 5 % of threshold |
| Measurement accuracy | +/- 10 % of the full scale value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit; +/- 0.5 % for time delay |
| Measurement error | +/- 0.1 %/°C with temperature variation; < +/- 1 % over the whole range with voltage variation |
| Input frequency | 0.0017…20 Hz |
| Response time | 15 ms max (on crossing the threshold) |
| Polarity | Reversible polarity on DC supply |
| Threshold setting | 10...100 % |
| supply voltage for sensor | 11.5...12.5 V |
| Maximum supply current for sensors | 40 mA for < 24 V AC at 25 °C; 40 mA for < 24 V DC at 25 °C; 50 mA for 24...240 V AC; 50 mA for 24...240 V DC |
| Impulse duration | >= 5 ms high state; >= 5 ms low state |
| Input compatibility | 3-wire sensor (E1) PNP or NPN, 12 V, 50 mA; NAMUR sensor (E2), 12 V, 1.5 kOhm; Voltage input (E1), 0...30 V, 9.5 kOhm, high state >= 4.5 V low state |
| Marking | CE : EMC 89/336/EEC; CE : 73/23/EEC |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 |
| operating voltage tolerance | - 15 % + 10 % Un |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Status LED | 1 LED green for power ON; 1 LED yellow for inhibit; 1 LED yellow for relay (R) |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Control type | Without test button |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Immunity to microbreaks | 50 ms |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | NF EN 60255-6; IEC 60255-6 |
| Product certifications | C-Tick; GOST; UL; GL; CSA |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Control Relays |
| Relay type | Speed control relays |
| Product or component type | Speed control relay |
| Relay name | RM35S |
| Relay monitored parameters | Overspeed; Underspeed |
| Time delay range | 0.6...60 s adjustable on energisation delay (tolerance: 0...10 % of the full scale value) |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum power consumption in VA | 5 VA AC |
| Measurement range | 0.05...0.5 s; 0.5...5 min; 1...10 min; 1...10 s; 0.5...5 s; 0.1...1 s; 0.1...1 min |
| Utilisation category | AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1 |
| time delay | Adjustable 0.6...60 s Ti- inhibition time delay upon startup |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.400 cm |
| Package 1 Width | 7.400 cm |
| Package 1 Length | 9.400 cm |
| Package 1 Weight | 133.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.181 kg |
Harmony Control. This speed monitor monitors a rotating axis for exceedance or undershoot of a set limit value (0.1-1200 rpm, 0.002-20 Hz). An additional sensor must be connected for detection (3-wire proximity switch PNP or NPN, NAMUR proximity switch, potential-free auxiliary switch, voltage signal 0-30 V). The monitoring type, the limit value and a switching delay are adjustable. An error memory can also be activated, which holds the message until a reset. The wide-voltage power supply (24-240 VAC/DC) enables universal use. The cable connection is made via screw terminals.