Schneider Electric RM35S0MW, EAN: 3389119405256

Schneider Electric RM35S0MW speed monitor 24-240 V

Industrial Material > Control devices / Pilot devices > Initiators, inductive / capacitive

Schneider Electric RM35S0MW speed monitor 24-240 V

Lieske Part No. 601986
Mfg Part No RM35S0MW
EAN-Code 3389119405256
Manufacturer Schneider Electric
Here only 168,63 EUR
200,67 EUR incl. VAT

Further information for Schneider Electric RM35S0MW speed monitor 24-240 V

Complementary
rest time in memory mode50 ms contact S2 in memory mode on time delay; 1 s supply Un in memory mode on time delay
Maximum switching voltage250 V AC/DC
[Un] rated nominal voltage24...240 V AC/DC 50/60 Hz, non self-powered
Supply voltage limits20.4…264 V AC/DC
Maximum power consumption in W3 W DC
Width35 mm
Output contacts1 C/O
Contacts materialCadmium free
nominal output current5 A
delay at power up0.05 s
Hysteresis5 % of threshold
Measurement accuracy+/- 10 % of the full scale value
Repeat accuracy+/- 0.5 % for input and measurement circuit; +/- 0.5 % for time delay
Measurement error+/- 0.1 %/°C with temperature variation; < +/- 1 % over the whole range with voltage variation
Input frequency0.0017…20 Hz
Response time15 ms max (on crossing the threshold)
PolarityReversible polarity on DC supply
Threshold setting10...100 %
supply voltage for sensor11.5...12.5 V
Maximum supply current for sensors40 mA for < 24 V AC at 25 °C; 40 mA for < 24 V DC at 25 °C; 50 mA for 24...240 V AC; 50 mA for 24...240 V DC
Impulse duration>= 5 ms high state; >= 5 ms low state
Input compatibility3-wire sensor (E1) PNP or NPN, 12 V, 50 mA; NAMUR sensor (E2), 12 V, 1.5 kOhm; Voltage input (E1), 0...30 V, 9.5 kOhm, high state >= 4.5 V low state
MarkingCE : EMC 89/336/EEC; CE : 73/23/EEC
Overvoltage categoryIII conforming to IEC 60664-1
Insulation resistance> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
[Ui] rated insulation voltage250 V conforming to IEC 60664-1
operating voltage tolerance- 15 % + 10 % Un
Supply frequency50/60 Hz +/- 10 %
Operating positionAny position without derating
Connections - terminalsScrew terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialPolycarbonate
Status LED1 LED green for power ON; 1 LED yellow for inhibit; 1 LED yellow for relay (R)
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability100000 cycles
Mechanical durability30000000 cycles
Control typeWithout test button
Contractual warranty
Warranty (in months)18
Environment
Immunity to microbreaks50 ms
Electromagnetic compatibilityEmission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
StandardsNF EN 60255-6; IEC 60255-6
Product certificationsC-Tick; GOST; UL; GL; CSA
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-20…50 °C
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protectionIP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Dielectric test voltage2 kV AC 50 Hz
Non-dissipating shock wave4 kV
Logistical informations
Country of originID
Main
Range of productHarmony Control Relays
Relay typeSpeed control relays
Product or component typeSpeed control relay
Relay nameRM35S
Relay monitored parametersOverspeed; Underspeed
Time delay range0.6...60 s adjustable on energisation delay (tolerance: 0...10 % of the full scale value)
Switching capacity in VA1250 VA
Minimum switching current10 mA at 5 V DC
Maximum power consumption in VA5 VA AC
Measurement range0.05...0.5 s; 0.5...5 min; 1...10 min; 1...10 s; 0.5...5 s; 0.1...1 s; 0.1...1 min
Utilisation categoryAC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1
time delayAdjustable 0.6...60 s Ti- inhibition time delay upon startup
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.400 cm
Package 1 Width7.400 cm
Package 1 Length9.400 cm
Package 1 Weight133.000 g
Unit Type of Package 2S03
Number of Units in Package 248
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.181 kg
Harmony Control. This speed monitor monitors a rotating axis for exceedance or undershoot of a set limit value (0.1-1200 rpm, 0.002-20 Hz). An additional sensor must be connected for detection (3-wire proximity switch PNP or NPN, NAMUR proximity switch, potential-free auxiliary switch, voltage signal 0-30 V). The monitoring type, the limit value and a switching delay are adjustable. An error memory can also be activated, which holds the message until a reset. The wide-voltage power supply (24-240 VAC/DC) enables universal use. The cable connection is made via screw terminals.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/601986
qrcode für Schneider Electric RM35S0MW speed monitor 24-240 V