| Complementary |
| Reset time | 8 s |
| Maximum switching voltage | 250 V AC/DC |
| [Us] rated supply voltage | 24...240 V AC/DC |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Supply voltage limits | 20.4…264 V AC; 21.6…264 V DC |
| Maximum power consumption in W | 0.6 W DC |
| Resistance across terminals | 1.33 kOhm at temperature |
| Width | 35 mm |
| Output contacts | 1 C/O |
| Contacts material | Cadmium free |
| nominal output current | 5 A |
| delay at power up | 0.2 s |
| Measurement accuracy | +/- 2 °C |
| Temperature probe type | Pt 100 - 3-wire |
| Installed device | Pt 100 probe cable length |
| Marking | CE : EMC 89/336/EEC; CE : 73/23/EEC |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 |
| operating voltage tolerance | - 10 % + 10 % Un DC; - 15 % + 10 % Un AC |
| Supply frequency | 50/60 Hz +/- 10 % |
| Insulation | Galvanic insulation between supply and measurement |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| local signalling | 1 LED green for power ON; 1 LED yellow for correct temperature (high R1); 1 LED yellow for correct temperature (low R2) |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Control type | Without test button |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Immunity to microbreaks | 10 ms |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | IEC 60255-6; NF EN 60255-6 |
| Product certifications | GOST; GL; C-Tick; UL; CSA |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Control Relays |
| Relay type | Temperature control relays |
| Product or component type | Elevator machine room temperature control relay |
| Product specific application | For elevator machine rooms and 3-phase supplies |
| Relay name | RM35AT |
| Relay monitored parameters | Under temperature: -1...11°C; Over temperature: 34...46°C |
| Time delay range | 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value) |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum power consumption in VA | 3.5 VA AC |
| Utilisation category | AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1 |
| time delay | Adjustable 1...10 s Tt- time delay upon fault |
| Measurement range | +/- 1...46 °C |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.0 cm |
| Package 1 Width | 4.6 cm |
| Package 1 Length | 9.7 cm |
| Package 1 Weight | 127.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 6.732 kg |
This monitoring relay is used for temperature monitoring in the technical rooms of elevators and lifts in accordance with EN 81. The temperature is monitored using a separate Pt100 sensor. A lower and upper limit value can be set in the temperature range +5 to +40°C. A drop-out delay for the output relay with a changeover contact can be set.