| Additional features |
| Power quality analysis | Complies with EN 50160: 2010 conformity report; complies with IEEE 519: 2014 conformity report; complies with IEC 61000-4-30: Class S power quality measurement; up to the 63rd harmonic; harmonic distortion; waveform capture; detection of voltage sags and overvoltages; programmability (logical and mathematical functions); complies with IEC 62586 power quality monitoring; complies with IEC 61000-4-15 disturbance direction detection; rapid voltage change |
| Device application | Capture of S0 pulses for measurement of water, air, gas, electricity, steam; current monitoring; data aggregation; revenue settlement |
| Measured value type | current; voltage; frequency; total active and reactive power; total apparent power; total power factor; active and reactive power per phase, RMS; apparent power per phase, RMS; power factor per phase, RMS; active and reactive energy; apparent energy |
| Supply voltage | 20 - 60 V DC ± 10 % |
| Network frequency | 50 Hz; 60 Hz |
| [In] Rated current | 10 A; 1 A; 5 A |
| Pole description | 1P + N; 3P; 3P + N |
| Power consumption in W | 17 W |
| Display type | Without display |
| Scanning interval | 256 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm); current (impedance 0.3 mOhm) |
| Measuring voltage | 57…400 V AC 42 - 69 Hz between phase and neutral; 100…690 V AC 42 - 69 Hz between phases |
| Measuring range for frequency | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC; 3 digital 60 V DC |
| Accuracy of measurement | Current ± 0.1 %; Voltage ± 0.1 %; Active energy ± 0.2 % |
| Accuracy class | Class 0.2S active energy corresponds to IEC 62053-22; Class 0.2 active energy corresponds to ANSI C12.20; Class 0.2 active power corresponds to IEC 61557-12; Class 0.5S reactive energy corresponds to IEC 62053-24; Class 0.5 power factor corresponds to IEC 61557-12; Class 0.2 voltage corresponds to IEC 61557-12; Class 0.2 current corresponds to IEC 61557-12; Class 0.2 frequency corresponds to IEC 61557-12; Class 0.2 active energy corresponds to IEC 61557-12 |
| Number of outputs | 1 impulse |
| Displayed information | Voltage; current; frequency; power; energy consumption; harmonic distortion |
| Communications protocol | Modbus RTU at 115 kBaud - 2-wire; ION at 115 kBaud - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004; DLMS |
| Support for communication interfaces | Ethernet; Screw terminal block: RS485; Mini-B-USB: USB |
| Communication network type | IPv6 (Internet protocol) |
| Data logging | Sequence of event recording; trend curves/forecasts; harmonic logs; timestamping; GPS synchronization; waveform logs; minimum/maximum values of real-time values; capture of voltage sags and overvoltages; data logs; event recording; alarm logs; 50 data loggers |
| Memory capacity | 512 MB |
| Web services | Customizable homepage; uploading/downloading files via FTP; uploading/downloading files via SFTP; web server; alarm notification by email; display of captured waveform (FTP); display of captured waveform (web); HTTPS server |
| Communication service | NTP time synchronization; E-mail notification via SMTP; RSTP support; DHCP; SNMP; PTP time synchronization |
| Cybersecurity | Activation/deactivation of communication ports; robust security protocols; hardening; password protection; Syslog logging support |
| Mounting mode | Plug-in |
| Mounting bracket | DIN rail |
| Installation type | Indoor installation |
| Installation category | III |
| Safety design | III400…690 V complies with IEC 61010-1:Ed. 3; III400…690 V complies with EN 61010-1:Ed. 3; III347…600 V complies with UL 61010-1:Ed. 3; III347…600 V complies with CSA C22.2 No. 61010-1:Ed. 3 |
| Standards | IEC 61326-1; IEC 62053-22; IEC 62053-24; IEC 62052-11; IEC 61557-12; IEEE 1588; IEC 62586 |
| Product certifications | CE; CULus; N998 |
| Width | 90,5 mm |
| Depth | 90,8 mm |
| Height | 90,5 mm |
| Product weight | 528 g |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | PowerLogic |
| Product name | PowerLogic ION7400 |
| Product or component type | Power meter |
| Device short name | ION7413 |
| Model type | Standard |
| Mounting |
| Degree of protection (IP) | IP30 corresponds to IEC 60529 |
| Relative humidity | 5…95 % |
| Operating ambient temperature | -25…70 °C |
| Ambient temperature during storage | -40…85 °C |
| Operating altitude | 3.000 m |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 14,000 cm |
| VPE 1 width | 14,000 cm |
| VPE 1 length | 18,500 cm |
| Packaging weight (Lbs) | 1,030 kg |
| VPE 2 type | S03 |
| VPE 2 quantity | 6 |
| VPE 2 height | 30,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 6,621 kg |
| VPE 3 type | P12 |
| VPE 3 quantity | 48 |
| VPE 3 height | 45,000 cm |
| VPE 3 width | 80,000 cm |
| VPE 3 length | 120,000 cm |
| VPE 3 weight | 64,968 kg |
ION7400 series power analyzer for front installation in low and medium voltage applications without display. Installation on DIN rail, accuracy class 0.2S. 4-quadrant measurement, import and export for active and reactive energy, active, reactive, apparent energy meters per phase and separate active energy meters with tariff selection via weekly timer, communication or contact. Current, voltage (average and per phase), current average, active, reactive, apparent power, power factor (total and per phase), power averages. Frequency, min and max values of the instantaneous values, max values of the current and power averages. Harmonic content THD I, THD U and TDD, harmonic analysis - measured values per phase with bar chart up to the 127th via software. Harmonic on the device display, up to the 63rd. Threshold monitoring and alarm: self-learning threshold with alarm via display or communication. 52 data recorders with 16 channels each for recording true RMS values (minute, second or 10ms values), event recorder with time stamp in milliseconds. Extended fault recorder function for network oscilloscope in the event of an event with up to 256 samples/period. for various trigger events via EcoStruxure Power Monitoring Expert with recording duration over 210 periods or > 4s with high sampling. High memory depth with 512 MB. Note: the accessories of the PM8000 are used as I/O modules, display and spare parts for ION7400.